16. Gas Conversion Cont.
The following table summarises the
correlation between gas type, knob set, LCD
display.
GAS
KNOB
position
LCD
Natural gas G20
1
01
LPG G30-G31
7
07
Example: If the supplied gas is LPG
(G30-G31) and the boiler is setup to operate
with natural gas (G20) turn the knob 8 in
Figure 16.4 as shown in Figure 16.9.
Figure 16.9
Gas type
Gas type
Natural
Gas
LPG
Setting No.
• The following will appear on the LCD
display (the sequence
P05
alternates with
07
).
Figure 16.10
• Once the type of gas is set, the confirmation
that it was stored occurs automatically,
after 5 seconds, with
OK
appearing on
the LCD display.
Figure 16.11
Gas setting - second step
• Press the reset button 6 Figure 16.4
to access the valid parameter
P06
for
setting the type of gas (second level); the
following will appear on the LCD display
(the sequence
P06
alternates with
01
).
Figure 16.12
• To change the setting, turn the hot water
temperature regulation knob 8 in Figure
16.4 to the preselected position see also
Figure 16.9.
The following table summarises the
correlation between gas type second level,
knob set, LCD display.
GAS
KNOB
position
LCD
Natural gas
G20
1
01
LPG G30-G31
7
07
• The following will appear on the LCD
display (the sequence
P06
alternates with
07
).