5. Instructions For Use Cont.
5.3 Lighting/Operating Instructions:
Warnings: Do not attempt to start the boiler unless all cleanout doors are secured
and sealed. Do not attempt to light the burner by hand.
1 Check that the cocks connected to the
gas inlet pipe and to the supply cold wa-
ter inlet pipe (see section 3.3 for pipes)
are open.
2 Power the boiler electrically by setting the
power switch foreseen in the installation.
The LCD display shows the sequence
(figure 5.2).
3 If the appliance will not operate, follow
the extinguishing instructions on page 14
and call your service technician or gas
supplier.
Figure 5.2
5.4 Temperature unit setting (°C or °F):
The Function switch and Central heating temperature adjustment (7) knob must be in OFF
position.
Press the boiler reset/setting button (6) and simultaneously rotate the domestic hot water tem-
perature control (8) knob to:
• position 1 for °C unit (figure 5.3)
• position 7 for °F unit (figure 5.4)
By releasing the boiler reset/setting button (6), the display indicates the temperature in the
chosen unit.
Figure 5.3
6
7
8
Figure 5.4
6
7
8