16 RIVA FP USER MANUAL
6. Useful Advice Cont.
6.4 External Cleaning:
• Before performing any cleaning, disconnect the appliance from the electrical mains, using
the dedicated circuit breaker or serviceman’s switch located adjacent to the appliance.
• To clean the external panels, use a cloth soaked in soapy water. Do not use solvents, abra-
sive powders or sponges.
• Do not carry out cleaning of the appliance and/or its parts with readily
fl
ammable substanc-
es (for example petrol, alcohols, naphtha, etc.).
6.5 Operational Faults:
If the lock-out signal lamp comes on:
• This indicates that the safety lock-out 1
(Fig. 6.2) has stopped the boiler
• To re-start the boiler, it is necessary to
turn the function selector B in the position
and then press the boiler reset button
2 (Fig. 6.2).
• For the
fi
rst light up and following main-
tenance procedures for the gas supply, it
may be necessary to repeat the resetting
operation several times so as to remove
the air present in the pipework.
Figure 6.2
If noises due to air bubbles are heard during operation:
• You should check that the pressure on the temperature and pressure gauge (Fig. 5.1 on
page 9) is not below the correct setting.
• If
required,
fi
ll up the system correctly, as described in the section 5.2 of this manual.
• Bleed any air present in the radiators, if necessary.
If the pressure on the temperature and pressure gauge (Figure 5.1 on page 9) has
gone down:
• It is necessary to
fi
ll up the appliance with water again, so as to raise the pressure to an
adequate level as described in the section 5.2 of this manual.
• If
fi
lling up with water has to be done very frequent, have the system checked for leaks.