Riva Plus Manual
23
C
Alternative separate kit (Exhaust outside & intake inside)
Test Ports
Exhaust Collar
Exhaust Elbow
Exhaust Pipe
Rubber Wall Trim (2X)
Exhaust Pipe End Cap
Air Intake Elbow
Air Intake Pipe
Air Intake Collar
Figure 9.5 (Twin Pipe Φ 3.25 in)
This configuration of the twin pipe kit allows to discharge the exhaust gasses outside. The air
supply is obtained with an air intake pipe. This allows to take air from the room where the
boiler is installed.
If either an additional 45° or 90° accessory elbow is used then the maximum permissible
lenght of either pipe must be reduced by 3.0 ft or 5.4 ft respectively.
Note: When utilizing this option, see page 14 for room ventilation details.
Installation:
•
Drill hole C (on the wall template) through the outside wall that is less than 18” thick.
•
Cut the pipe as necessary so that no more than 6” protrudes from the house.
•
Slide the exhaust pipe through the hole.
•
Slide one rubber wall trim piece on the pipe from inside and one from outside.
•
Attach each collar to the boiler with the gasket and screws provided.
•
Insert each elbow into its corresponding collar.
•
Connect each pipe to its corresponding elbow.
9. Venting Cont.