M
ANUAL
FOR
NOZ2 G
AS
-
FIRED
S
ERVICING
Manual version 4.0 (06-12-2016)
en-49
en
8.1.3 Removing the discharge cone
The system fan is located in the discharge cone.
Disconnecting the discharge cone
In order to remove it:
• Remove screw
1
.
• Slightly loosen the screws
2
.
• Turn the cone slightly and remove it.
8.2
Fuses
Specifications of the fuses
L
OCATION
D
ESCRIPTION
S
PECIFICATION
1
fuses F1 and F2 for the
electronics
T 5A (2x)
2
fuses F7 and F8 for the
power supply
T 3.15 A (2x)