background image

 Bierkühl Oy

+358 440 178 111

 Pellonlaita 1, 50600 Mikkeli Finland  

www.boscleantec.com

Operation and Maintenance Manual
BOS® Cleantec Duct Cleaning Brushes

SIVU 7

OPERATING AND SAFETY INSTRUCTIONS

PLEASE CAREFULLY OBSERVE THE FOLLOWING BEFORE AND DURING OPERATION:

The machine operator must ensure that the machine is fit for the intended purpose.

The machine operator must ensure that the air supply matches the ratings on the CE plate.

The air must be dry and clean.

All regulatory requirements must be observed.

There  must  be  no  flammable  particles  nor  danger  of  explosion  present  in  the  operating
environment.

No flammable or explosive materials or substances must be used or stored at the location
where the machine is used.

The machine must be protected from moisture, vibration and water.

Only use spare parts that are suitable for the machine (are approved by the manufacturer).

Do not cover the machine during operation.

The machine must be kept as clean as possible.

Do not stay continuously in the immediate vicinity of a machine in operation.

The machine must not be used in the vicinity of explosive, toxic or corrosive gases.

The operating temperature must not 40°C or fall below -20°C.

The machine must not be modified in any way.

It is recommended that these machines are operated by two persons at a time, to avoid accidents
caused by the force of the rotating shaft and brush.

The shaft may only be rotated while the brush is inside a duct. Before starting work, make sure the
brush is properly attached.

The  person(s)  performing  the  work  must,  depending  on  the  work  performed,  wear  respiratory
protection,  a  helmet,  hearing  protection,  safety  goggles,  clothing  and  footwear  as  well  as  other
personal protective equipment.

Summary of Contents for BOS Cleantec

Page 1: ...es These may only be used in dry conditions in non hazardous areas This item is not suitable for people whose physical abilities perception and intellectual capacity are weak or compromised including children except under the supervision of a responsible and able person who has read these User Instructions Children must be kept away from the machine Disclaimer This manual has been reviewed but 100...

Page 2: ...perator and the person in charge of the machine are liable for any damage resulting from use in breach of regulations The manufacturer accepts no liability for any consequences of using the machine in breach of the instructions Always store the manual where the operator can refer to it Read the manual carefully before machine installation and commissioning Observe the operating and maintenance ins...

Page 3: ... Continously adjustable Noise 78 5 dB A Controls Manual air valve Brush direction control Air valve Brush connector M 12 Dimensions height width length mm 1200 500 1060 Weight 44 kg Cleaning shaft length 40 m Cleaning shaft LDPE outer sheath 11 mm glass fibre rod 2 12 10 PaP40 1 10 8 Pa12P40 Pressure 6 bar pressure Air flow 300 600 i min Material housing drum Painted steel marine grade aluminium E...

Page 4: ... USE THE MACHINE IN DRY CONDITIONS IN NON HAZARDOUS AREAS Protect the machine against moisture and vibration Protect the machine against water during cleaning The removal and any modification of safety features is strictly prohibited The information on the type plate must be observed during maintenance and when ordering spare parts Observe national regulations Observe local regulations governing t...

Page 5: ...Bierkühl Oy 358 440 178 111 Pellonlaita 1 50600 Mikkeli Finland www boscleantec com Operation and Maintenance Manual BOS Cleantec Duct Cleaning Brushes SIVU 5 CONSTRUCTION AND CONTROLS BOS Cleaner 750p ...

Page 6: ...ylon centter 200 1000 mm PEH 300 PES Ø 0 5 mm Combination brush with nylon center and disc 200 400 800 1000 mm PEH 300 PES Ø 0 5 mm nylon PA 6 6 Ø 0 75 mm Hard brush with nylon center 300 600 mm PEH 300 nylon PA 6 6 Ø 1 0 mm Soft brush for small ducts Pes bristle 0 35 mm M 12 125 350 mm Brush with nylon center tynex nylon bristle 200 400 800 1000 mm High volume air jetting nozzle for BOS Cleaner 7...

Page 7: ...moisture vibration and water Only use spare parts that are suitable for the machine are approved by the manufacturer Do not cover the machine during operation The machine must be kept as clean as possible Do not stay continuously in the immediate vicinity of a machine in operation The machine must not be used in the vicinity of explosive toxic or corrosive gases The operating temperature must not ...

Page 8: ...s when the temperature is at the correct level When not in use the machine must be disconnected from the pneumatic system Inspect the condition of the ducts for damage before starting work and remove any obstacles 4 Operation Before starting any work make sure the work area is clear and free of obstacles and any superfluous personnel Wear personal protective equipment For efficient cleaning create...

Page 9: ...be serviced at intervals of one year If any mechanical faults are discovered the machine must be serviced without delay During handling and transport the machine must be protected to prevent further damage and personal injuries Routine maintenance and care covers cleaning the machine and checking the condition of the shaft A shaft with minor damage can be repaired using a heat shrink tube Check th...

Page 10: ...nance or use All maintenance and repair work on the machine has been performed by the manufacturer or an authorised representative The manufacturer accepts no liability for any maintenance work performed by a third party A warranty claim has been submitted in writing The warranty does not cover defects resulting from normal wear and tear negligence improper use or maintenance repair works not perf...

Page 11: ... compatible recycling point The valuable materials and components contained in the machine should be recycled and reused If an appropriate recycling point cannot be found the product can also be returned to the seller or manufacturer for recycling Metal parts housing and motor can be recycled as scrap metal Electronic parts air motor air valve should be taken to an authorised recycling facility Ot...

Page 12: ...en designed to comply with the Finnish Government Decree on the safety of machinery 400 2008 and meets the quirements of the Machinery Directive 2006 42 EY We also declare that the following Directives and harmonised standards have been applied Essential characteristics and performance Harmonised technical specification Safety of machinery SFS EN ISO 12100 2010 Decree on the safety of machinery Fi...

Reviews: