3.4.2 BY-PASS ADJUSTMENT
Figure 3.4.2
– By-pass action to Angular stroke / Quick
operation time diagram
Remove the protection cap from adjusting needle-valve and turn it
clockwise to increase throttling-action and consequently to slow the
last part of cylinder stroke. To decrease throttling-action, turn the
needle for by-pass in anti-clockwise direction .
To reduce more the operating time (higher speed) unscrew both By-
pass screws (see diagram in fig. 3.4.2)
To correctly calibrate the quick operation time it is necessary to
arrange the data acquisition using a position transmitter and an
ascillographic recorder compatible with required time. If specific
signals are built on by specific instrumentation please refet to
dedicated documentation
Two By-pass valves open
One By-pass valve open
Two By-pass valves closed