For the transport of OLGAS with hydraulic manual handpump, when it was necessary put
in horizontal position the tank of MHP, to avoid leakage on oil level stick, substitute these
with a blind-plug during the transport (a specific warning label for transport in horizontal
position is attached on the MHP body); remove the blind plug and restore the dipstick
before operate the actuator with MHP.
Biffi hydraulic manual handpump must be maintained with tank under the handpump to
operate the actuator with MHP correctly.