Installation, Operation and Maintenance Manual
MAN 608 Rev. 5
December 2020
Operation and Use
25
Section 3: Operation and Use
3.5
Calibration of Micro-switches (If Foreseen)
Calibration of Micro-switches (If Foreseen)
!
WARNING
Refer only to technical documentation related to installed switch-box model.
NOTICE
For mounting interface dimension of the Limit Switch box on the cover of the actuator,
please refer to TN1163V (for metric dimension) or TN1163VU (for imperial dimension).
NOTICE
Operate only the micro-switch corresponding to the direction of operation being carried
out, as clearly reported on the micro-switch. End of stroke microswitches should be
operated before the stop of the stroke of the actuator due to mechanical stops. Adjust the
relative cams properly.