6.   Appendix 

 

ORM0043_2 

Modulating Controller Application Manual 

Page 11 

 

  6.1   System Inputs 

Clear Fault

 

 

Set active to clear a pump overrun fault 

Auto Mode Switch

 

Set active to force the controller into Automatic mode 

Man Mode Timer

 

Set active to force the controller into Automatic mode after a specified time 

4-20mA Cmd Ctrl

  

Set active to modulate based on the 4-20mA command signal 

Remote Cmd Ctrl

  

Set active to modulate based on a fixed remote command signal 

Remote Override

  

Set active to override fault positioning using remote open and close signals 

Remote Open

 

 

Set active to override positioning and open the actuator 

Remote Close

 

 

Set active to override positioning and close the actuator 

Manual Enable

   

Set active to position actuator using the switch in manual mode 

Manual Fast Pos

   

Set active to ignore pulse zones when positioning in manual mode 

Fault Open

 

 

Set active to open the actuator when a fault occurs 

Fault Close

 

 

Set active to close the actuator when a fault occurs 

Fault Fast Pos

 

 

Set active to ignore pulse zones when positioning due to a fault 

Hard Seat Open

   

Set active to force the actuator open when fully open 

Hard Seat Close

   

Set active to force the actuator closed when fully closed 

Hard Seat Fast

   

Set active to ignore pulse zones when hard seating 

Fail On Fdbk Flt

 

Set active to drive actuator based on fault settings when a feedback signal fault 

Fail On Cmd Flt

 

Set active to drive actuator based on fault settings when a command signal fault 

Common Fault

 

Set active when there is a signal indicating an external fault 

Pump On Demand

 

Set active to enable use of pump on demand features 

Run Pump To Opn

 

Set active to run the pump when the actuator is opening 

Run Pump To Clse

 

Set active to run the pump when the actuator is closing 

Pump On Pressure

 

Set active to enable use of pump on pressure features 

Press Swtch Ctrl

 

Set active to maintain accumulator pressure using pressure switches. Set off to maintain 
accumulator pressure using a pressure transmitter. 

Single Px Switch

 

Set active when a single pressure switch is used to maintain accumulator pressure 

Pump Start Swtch

 

Set active when at the minimum desired accumulator pressure 

Pump Stop Swtch

 

Set active when at the maximum desired accumulator pressure 

Pump Fault

 

Set active when the pump is indicating that it is in fault 

Fail On Pump

 

Flt

 

Set active to drive actuator based on fault settings when there is an issue with the pump 

Low Oil Level

 

Set active when there is a signal indicating a low oil level 

Lo Lvl Pump Lock

 

Set active to stop the pump when there is a low oil level signal 

High Oil Temp

 

Set active when there is a signal indicating a high oil temperature 

Hi Temp Pump Lock

 

Set active to stop the pump when there is a high oil temperature signal 

Manual Stop Pump

 

Set active to stop the pump when entering into manual mode 

Cmn Flt Stop Pmp

 

Set active to stop the pump when there is a common fault signal 

Supply Px Check

 

Set active to check that the supply pressure is above the minimum required pressure 

Fail On Low SPx

 

Set active to drive the actuator based on fault settings when there is a low supply pressure 

 

 

 

Summary of Contents for Orange EHPC210

Page 1: ...ower Limited The content of this document may not be used for purposes other than that for which it has been supplied and may not be reproduced either wholly or in part nor may it be used by or its co...

Page 2: ...m Values 13 6 4 System Times 14 6 5 HART Variables 14 This manual provides instruction on the setup and analysis of the modulating controller application Section 2 details specific actuator modules in...

Page 3: ...be linked to the input providing the actuator position signal which provides a calibrated 0 100 value In standard operation 4 20mA Cmd Input should be active meaning that the command value is taken f...

Page 4: ...or both limits of the pulse zone these being the set pulse zone Limit and when the command and actual position are equal Blnce A transfer function is then used within the application to set the requir...

Page 5: ...ide When the controller is in automatic mode if the actuator goes into fault the actuator can be forced to drive to a required location If Fault Open and Fault Close are both off or both are set activ...

Page 6: ...n the actuator will position based on the fault override settings High Pressure SP is a high pressure alarm set point which is used to indicate that the pressure has exceeded the maximum allowable acc...

Page 7: ...uator will position based on the fault override settings To reset Overrun Fault Clear Fault must be set active This immediately resets the fault and then Clear Fault is automatically set to off such t...

Page 8: ...settings because it cannot be certain the pressure has not dropped below the minimum allowable supply pressure 4 2 Controller Access Whenever the controller is powered on the Controller On output is s...

Page 9: ...Actuator is fully closed Pump Output Pump is running ACTUATOR POSITION Provides the current actuator position based on the analogue signal If the signal is in fault 0 0 will be shown COMMAND Provides...

Page 10: ...urrently present Below are the statuses that can be displayed Healthy Accumulator is operating within required limits Pump Output Pump is running Acc Press Fault Pressure signal is in fault Pump Fault...

Page 11: ...signal fault Common Fault Set active when there is a signal indicating an external fault Pump On Demand Set active to enable use of pump on demand features Run Pump To Opn Set active to run the pump w...

Page 12: ...mand signal is in fault Common Fault Set active when there is a signal indicating a common fault Pump Output Set active when the pump is required to run Pump Fault Set active when there is a signal in...

Page 13: ...ic DZ Value indicating how much the command signal must be less than the feedback position when the actuator is static before it starts to close Close Moving DZ Value indicating how much the feedback...

Page 14: ...e position when the actuator is opening Close Limit Move Time that the Close Solenoid pulses active when at the pulse zone limit when the actuator is closing Close Blnce Move Time that the Close Solen...

Reviews: