WWW.BIGASSFANS.COM ©2012 DELTA T CORP. DBA BIG ASS FAN ALL RIGHTS RESERVED
12’–24’ BASIC6
™
Installing the Electronic Programming Module (EPM)
WARNING: Install the EPM prior to applying power to the fan controller!
AVERTISSEMENT : Installer les MPE avant la mise sous tension du ventilateur.
7KH(30FRQWDLQVDOOSURJUDPPLQJLQIRUPDWLRQVSHFL¿FWRIDQRSHUDWLRQ,W
must
be installed prior to applying power to the fan controller.
This module is provided as part of the fan’s accessory kit.
To install the EPM,
disconnect the fan from power (refer to the position of the disconnect switch below). Insert the EPM in the location
shown below.
Note: The EPM module can only be inserted one way. Do not force it!
Electrical Installation (cont.)
U
/T1
V
/T2
W
/T3
PE
L1 L2 L3
L1
L2
L3
1 2 5 6
13A13B13C 14 30 16 17
25 4 11
1 2 5 6
13A13B13C 14 30 16 17
25 4 11
SCA ME
SCA ME
M
R F
RUN
STOP
AUTO
FWD
REV
WARNING
DO NOT USE THIS
DISCONNECT TO
START AND STOP THE
FAN. PERMANENT
DAMAGE WILL
RESULT!
Electronic
Programming
Module
If hanging multiple fans, ensure to install the exact EPM included in each fan’s packaging. EPMs are not
interchangeable!
Summary of Contents for Basic6
Page 1: ......
Page 50: ......
Page 63: ......
Page 64: ... 002781 01 002781 01 2348 Innovation Drive Lexington KY 40511 5 9 ...