Installing Guy Wires
1. Attach guy wire clamp
Position the clamp on the extension tube as close to the motor as possible, but no more than (4 ft) 1.2 m higher than the top of the
main fan unit. Refer to the diagram below. Secure the guy wire clamps with the Guy Wire Hardware.
Guy Wire Hardware (BAF-Supplied):
a. (2) 1/4-20 X 1” Carriage Bolt
b. (2) 1/4-20 Nylock Flange Nut
Guy Wire Clamps
a
b
4 ft
Ensure the guy wire clamps are
no higher than 4 ft (1.2 m) above
the top of the main fan unit.
Guy wires may not be included in your fan order. They are intended to restrain the fan’s lateral movement and are only
included in fan orders that have extension tubes 4 ft (1.2 m) or longer. Depending on the operational environment (wind,
mounting structure, etc.), guy wires may be needed regardless of extension tube length. If, during operation, any lateral
movement (wobbling) occurs, a guy wire kit should be purchased from Customer Service using the Optional Parts Order
form or by calling 1-877-BIG-FANS.