Turntable Lower
(Works
in line with above
function)
Turntable doesn’t lower
Side Gate Left or right or
Hooks retract pressure
transducer has not achieved
its trigger pressure
Decrease the appropriate
pressure transducer
Turntable Lift Rotary sensor
calibration
Re-calibrate Rotate Rotary
sensor (
Section
6.9
)
Turntable doesn’t lower all
the way
Turntable rotate rotary
sensor hasn’t achieved its
home position
Re-calibrate sensor/faulty
sensor
Wiring loom fault
Turntable rotate rotary
sensor Calibration
Re-Calibrate Sensor
Turntable doesn’t complete
its cycle
Turntable rotate Rotary
sensor
The rotary sensor will need
calibrating as it hasn’t
achieved its 0 degrees
(
Section
6.9
)
8
.0
Trouble
s
hooting
8
.
10
Auto Stack Troubleshooting Continued.
Fig. 1
4
9
46
Auto Tip Bed Down (Can operate in Manual Functions)
Function
Symptom
Cause
Fix
Tip Bed Down
Tip Bed Down does not
lower
Machine PTO Off
Turn PTO on (540)
Tip Bed Down proximity
sensor. (Do the below
functions carry on?)
The sensor may be
damaged which will cause
the machine to think that
the bed is already down.
(Section 6.8)
Turntable Retract
(Works in line with
above function)
The turntable does not
retract
Machine PTO Off
Turn PTO on (540)
Turntable Lower half
way
Turntable starts to lower
before the turntable has
retracted all the way
The turntable retract
proximity sensor.
The sensor may be broken
causing the turntable to
think that the turntable is
retract so it starts to lower.
(Section 6.8)
Side Gates LH/RH close
Side Gates LH/RH don’t
close at all
Turntable – Retract sensor
has not been triggered.
Adjust sensor appropriately
(Section 6.8)
Tip Bed Down proximity
sensor has not been
triggered
Adjust sensor appropriately
(Section 6.8)
Left and Right Side Gate
pressure transducer trigger
is set to low.
Increase Side Gate Left and
Right Trigger Pressure.
Turntable Rotate CCW
(Works in line with
above function)
Turntable does not rotate at
all
Side Gate Left or pressure
transducer has not achieved
its trigger pressure
Decrease the appropriate
pressure transducer
Turntable Rotate rotary
Sensor calibration
Re-calibrate Rotate Rotary
sensor
(Section 6.9)
Turntable rotate doesn’t
rotate all the way
Turntable Rotate Rotary
Sensor calibration
Re-calibrate Rotate Rotary
sensor
(Section 6.9)
Turntable Lower
Turntable doesn’t lower
Side Gate Left or right or
pressure transducer has not
achieved its trigger pressure
Decrease the appropriate
pressure transducer
Turntable Rotate has not
achieved its home position
Re-calibrate Rotate Rotary
sensor
(Section 6.9)
Turntable Lift Rotary sensor
calibration
Re-calibrate Rotate Rotary
sensor
(Section 6.9)
Turntable doesn’t lower all
the way
Turntable lift rotary sensor
hasn’t achieved its home
position
Re-calibrate sensor/faulty
sensor
(Section 6.9)
Wiring loom fault
8
.
1
1
Auto Tip Bed Down
Troubleshooting
Summary of Contents for Transtacker 4100
Page 61: ...58...
Page 62: ...59...
Page 63: ...11 0 Hydraulic Systems 11 4 Valve Block Schematic Fig 168 60...
Page 67: ...13 0 Maintenance 13 2 Pickup Grease Points Fig 172 64...
Page 68: ...13 0 Maintenance 13 3 Grab Arm Grease Points Fig 173 65...
Page 69: ...13 0 Maintenance 13 4 Turntable A Frame Grease Points Fig 174 66...
Page 70: ...13 0 Maintenance 13 5 Side Gate Grease Points Fig 175 67...
Page 71: ...13 0 Maintenance 13 6 Rear Clamps Grease Points Fig 176 68...
Page 72: ...13 0 Maintenance 13 7 Chassis Grease Points Fig 177 69...
Page 73: ...13 0 Maintenance 13 8 Platform Grease Points Fig 178 70...
Page 74: ...13 0 Maintenance 13 9 Axle Grease Points Fig 179 71...
Page 84: ...16 0 Operators Notes 81...
Page 85: ...82...
Page 86: ...83...
Page 87: ...84...