WWW.BIGASSFANS.COM © 2020 DELTA T LLC ALL RIGHTS RESERVED.
2
ASSEMBLY AND SETUP
CAUTION: Do not connect to a water source where water pressure exceeds
120 PSI. This will cause permanent damage to the cooler.
CAUTION: If using an extension cord, do not exceed the cord’s amperage
ratings. Undersized extension cords create excessive drops in voltage,
causing the electric motor to generate excess heat. This results in
inefficient motor operation and premature motor failure and will void the
warranty.
Installing the casters
1. Locate the package of four (4) casters and remove from box.
2. Lay box on its side and carefully open bottom of box.
Do not stand box upside
down.
3. Install the four casters.
4. Stand cooler up on casters and remove box.
The cooler has been factory tested and is ready to use. Place the cooler on level
ground with the casters locked to prevent inadvertent movement.
Connecting the water supply
The cooler comes equipped with a female garden hose water source connection.
Use a standard garden hose (not provided) to connect the water supply to the
cooler.
Connecting the electrical supply
Plug the cooler into a fused or breaker-protected circuit. Refer to the tables below
for circuit size and extension cord requirements.
Amperage and Circuit Requirements
Model
Volts +/- 10%
Frequency
Min. Circuit Size
Running
Amps
Cool-Space® 200
120 V
60 Hz
15 A
2.7 A
Three-Conductor Heavy Duty Extension Cord Requirements
Cord
Length
Cord Size
16 GA
14 GA
12 GA
10 GA
0–50 ft
(0–15 m)
13 A
18 A
25 A
30 A
50–100 ft
(15–30 m)
10 A
13 A
18 A
25 A