5
NOTE
1. All dimensions are from the surfaces of all tubes and couplings.
2. Clearances B, C, and D can be reduced by 50% after 25 ft (7.5 m) of tubing downstream from where the burner
and burner tube connect.
FIGURE 3: One Side Reflector
IRH 80
IRH 125
IRH 150
IRH 200
A
6" (16 cm)
6" (16 cm)
6" (16 cm)
8" (21 cm)
B
9" (23 cm)
9" (23 cm)
9" (23 cm)
18" (46 cm)
C
69" (176 cm)
82" (209 cm)
85" (216 cm)
102" (260 cm)
D
54" (138 cm)
65" (166 cm)
69" (176 cm)
73" (186 cm)
FIGURE 2: Level Reflector
IRH 80
IRH 125
IRH 150
IRH 200
A
6" (16 cm)
6" (16 cm)
6" (16 cm)
8" (21 cm)
B
38" (97 cm)
46" (117 cm)
50" (127 cm)
52" (133 cm)
C
65" (166 cm)
76" (194 cm)
79" (201 cm)
96" (244 cm)
D
38" (97 cm)
46" (117 cm)
50" (127 cm)
52" (133 cm)
FIGURE 4: Two Side Reflectors
IRH 80
IRH 125
IRH 150
IRH 200
A
6" (16 cm)
6" (16 cm)
6" (16 cm)
8" (21 cm)
B
25" (64 cm)
32" (82 cm)
35" (89 cm)
40" (102 cm)
C
71" (181 cm)
83" (211 cm)
87" (221 cm)
102" (260 cm)
D
25" (64 cm)
32" (82 cm)
35" (89 cm)
40" (102 cm)