12
Installing the resistance unit
Note:
Refer to the service instruction provided with the Elite resistance unit as well.
1.
First, install the resistance unit to the resistance unit base. Raise the mount and place the resistance unit on the mount with the
installation hole of the resistance unit properly positioned.
Fix it with the washers and bolts provided with the resistance unit.
2.
Install the resistance unit base to the base frame. Align the tire with the center of the resistance unit roller, and align the nuts
of the base frame with the screw holes in the bracket. Fix the bracket with the bolts (long) using a 6 mm Allen key, and lower
the height adjustment mount of the resistance unit. Finally, fix the top fixing plate to the base frame with the four bolts
(medium).
Tightening torque:
23.5 N·m {206 in. lbs.}
Resistance Unit
Bolt
Washer
1
2
3.
Attach the ground cable. Remove the bolt from the resistance unit, pass it through one end of the ground cable, and tighten
the bolt.
Then, fix the other end together with a ground cable equipped with a ground terminal to the base frame with the ground
cable fixing bolt.
Ground cable fixing bolt
To the ground terminal on
the wall side
4.
Finally, connect the cable of the main unit to the resistance unit.