background image

 

3

 

 

Connect each station to the switch by twisted-pair cable. 

Plug one RJ-45 connector into a RJ-45 port of the switch, 

and plug the other RJ-45 connector into the station’s network 

adapter. Power on the switch and then system is ready. 

For cable selection, refer to the following table. 

 

 

 

 

In making a switch interconnection, you could use any port to 

connect another switch with straight or crossover cable. As 

all the ports support auto MDI / MDI-X function, using a 

straight cable to make a switch-to-switch connection is 

allowed. 

 
For cable selection, refer to the following table

 

 

Network Speed  Cable Type 

Max. Length 

10Mbps 

Cat. 3, 4, 5 UTP/STP 

100 meters 

100Mbps 

Cat. 5 UTP/STP 

100 meters 

Summary of Contents for BiPAC ES05

Page 1: ...BiPAC ES05 ES08 5 Port 8 Port Green Ethernet Desktop Switch User manual ...

Page 2: ...supports auto MDI MDI X function Each port could be used to connect to another switch or hub with no crossover RJ 45 cable Store and forward switching mode promises the low latency plus eliminates all the network errors including runt and CRC error packets To work under full duplex mode transmission and reception of the frames can occur simultaneously without causing collisions as well as double t...

Page 3: ...for LED definition 5port 8port LED Status Operation Steady Green Power is on Power Off Power is off Steady Green The port is connected Blinking Green The port is transmitting receiving data Link Act Off No connection Rear Panel 5port 8port ...

Page 4: ...cable selection refer to the following table In making a switch interconnection you could use any port to connect another switch with straight or crossover cable As all the ports support auto MDI MDI X function using a straight cable to make a switch to switch connection is allowed For cable selection refer to the following table Network Speed Cable Type Max Length 10Mbps Cat 3 4 5 UTP STP 100 met...

Page 5: ...thernet Ports 8 10 100Mbps RJ 45 Fast Ethernet Ports Uplink Auto MDI MDI X Auto crossover Network Speed 10 100Mbps Full Half duplex mode auto detection MAC Address Table 2K MAC address entries 5port 1K MAC address entries 8port Memory 384 K bits 5port 768 K bits 8port Power Supply External Power adapter 5VDC 0 6A EMI CE FCC and VCCI class B ...

Page 6: ...n is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE Mark Warning This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class B for ITE the essential protection requirement of Council Directive 89 33...

Reviews: