background image

3

do not handle or use until safety precautions 
concerning methyl ethyl ketone Peroxides in 
the manufacturer’s literature have been read 
and understood.

contact with foreign materials, especially 
strong mineral acids, metals (including certain 
equipment and containers) or metal salts, or 
exposure to heat above 135° F (57° c) may 
lead to violent decomposition, releasing 
flammable vapors which may self-ignite.

do not get into eyes or on skin or clothing. 
Wear eye and skin protection when handling. 
Avoid breathing mist. use with adequate 
ventilation. Store only it in the original  
closed container. Wash hands thoroughly  
after handling. Protect from direct sunlight, 
heat, sparks and other sources of ignition. 
Prevent contamination with foreign materials. 
do not add to hot materials.

To maintain the chemical activity store below 

100° F (38° c).

In case of fire, use water spray, foam or dry 
chemical. 

In case of spill or leak, absorb or blend with 
inert, non-combustible material. Put in suitable 
container. dispose of immediately in 
accordance with federal, state and local 
regulations.

do not reuse container as some of the original 
hazardous contents may still be present. 

Follow the above precautions in handling. 

HAloGenATed HydrocArbon  
SolvenTS cAn cAuSe An exPloSIon 
WHen In conTAcT WITH AlumInum 
comPonenTS oF A PreSSurIzed or 
cloSed FluId SySTem (PumPS, HeAT-
erS, FIlTerS, etc.)

The same possibility of an explosion is possible 
with the galvanized coatings in pressure tanks. 
The possibility of a non-flammable explosion 
increases greatly at high operating temperatures.

The explosion could be of sufficient strength to 
cause bodily injury, death, and substantial 
property damage.

cleaning agents, coatings, or adhesives may 
contain HAloGenATed HydrocArbon 
SolvenTS. cHeck WITH your SolvenT 
And PAInT SuPPlIer.

If you are now using a Halogenated Hydrocarbon 
Solvent in a pressurized fluid system with 
aluminum components or galvanized wetted 
parts, the following steps should be taken 
immediately:

1.  remove all pressure; drain and disconnect 

the entire system.

2.  Inspect and replace all corroded parts.

3.  contact your solvent supplier for a  

non-HAloGenATed SolvenT to  
flush and clean the system of all residues.

HAloGenATed Solvents are defined as any 
hydrocarbon solvent containing any of the 
following elements:

 cHlorIne  “cHloro” 

(cl) 

 

bromIne “bromo” 

(br) 

 

FluorIne “Fluoro” 

(F) 

 

IodIne “Iodo” 

(I)

of those listed, the chlorinated Solvents will 
most likely be the type used as a cleaning agent 
or solvent in an adhesive or coating. The most 
common are:

meTHylene cHlorIde

1,1,1, TrIcHloreTHAne

PercHloreTHylene

Although stabilizers have been added to some 
of the solvents to reduce their corrosive effect, 

we are aware of none that will prevent these 

solvents from reacting under all conditions 

with aluminum components or galvanized 

coatings.
Previous use of the solvents under pressurized 
conditions, without incident, does not necessarily 
indicate that it can be considered safe.

model 2100 Gw Gun is  

constructed with components of aluminum alloy  

and should not be used with any  
halogenated hydrocarbon solvents.

  Warning

!

  Warning

!

when using Binks equipment with  

methyl ethyl Ketone peroxide in plasticizer 

oBserVe the following precautions

CorrosiVe to the eyes – may Cause Blindness. 

may Be fatal if swallowed. stronG irritant. 

Contamination or heat may lead to fire or 

explosiVe deComposition. ComBustiBle.

read & understand the material safety data sheet from  

material supplier

FirSt aiD

EYES 
Wash immediately (seconds count) with 
water and continue washing for at least 
15 minutes. obtain medical attention.

SKIN 
Wash with soap and water. remove 
contaminated clothes and shoes and again 
wash thoroughly with soap and water.

SWALLOWING 
Administer large quantities of milk or 
water. obtain immediate medical attention 
for lavage.

Summary of Contents for 2100 gw

Page 1: ...tput is controlled by two variables 1 Nozzle orifice size air or resin 2 Air and or resin pressures Precise resin pressures can best be controlled by a fluid regula tor tank or pump pressure Minute adjustments in flow can be made with the control screw 17 which restricts the travel of the resin needle 15 Curative Volume Output Output of the curative is controlled by four variables 1 Curative nozzl...

Page 2: ...re are moving parts Know Where and How to Shut Off the Equipment in Case of an Emergency Pressure Relief Procedure Always follow the pressure relief procedure in the equipment instruction manual Wear Safety Glasses Failure to wear safety glasses with side shields could result in serious eye injury or blindness De energize DEPRESSURIZE Disconnect and Lock Out All Power Sources During Maintenance Fa...

Page 3: ... If you are now using a Halogenated Hydrocarbon Solvent in a pressurized fluid system with aluminum components or galvanized wetted parts the following steps should be taken immediately 1 Remove all pressure drain and disconnect the entire system 2 Inspect and replace all corroded parts 3 Contact your solvent supplier for a non halogenated solvent to flush and clean the system of all residues Halo...

Page 4: ... require separating the valve and catalyst bottle assemblies from the gun at the swivel 35 Vertical Adjustment Axis Horizontal Adjustment Axis Horizontal Adjustment Arc Vertical Adjustment Arc Loosen Swivel Nut for Vertical Adjustment 26 2 28 20 18 21 29 7 3 15 16 17 1 13 14 12 11 10 5 4 9 8 22 19 25 24 6 23 27 CAUTION The fluid inlet is not meant to be removed or replaced 30 59 Position vent at r...

Page 5: ... gasket 1 14 see footnote 1 fluid nozzle 1 15 see footnote 2 fluid needle 1 16 54 1347 5 n spring 1 17 54 1007 control screw 1 18 54 304 5 n spring 1 19 20 3757 n o ring 1 20 54 738 5 n packing 1 21 54 1014 5 n pin 1 22 54 1025 n valve stem assembly 1 23 82 126 5 screw 1 24 82 135 5 nut 1 25 82 158 5 n packing 1 26 54 1780 quick change sideport conTrol optional 1 27 jga 132 plug optional 1 28 82 4...

Page 6: ...described in previous paragraph Replace stem insert new packing and reassemble in reverse order Cleaning the Gun when used with remote pressure cup Shut off the air supply to the pressure cup and release the pres sure in the cup Leave the pressure release vent open Hold a piece of cloth over the gun nozzle and depress the trigger The air will back up through the resin nozzle and force the resin ou...

Page 7: ...B 568 9 5 14 1 19 1 12 0 2 ZAHN 45 6801 2 8 mm 46 6032 47 56800 Model 105 1236 2100 GW REMOTE PRESSURE OUTFIT 2 QUART 2 1 1 2100 4307 9 2100 GW GUN 66SS X 66SD 1 77 2936 2 80 295 2 QT STEADI GRIP PRESSURE CONTAINER 1 77 2823 3 71 1210 AIR HOSE ASSEMBLY 1 4 71 3380 FLUID HOSE ASSEMBLY 1 ITEM PART PART NO NO DESCRIPTION QTY SHEET Parts List When ordering please specify Part No 3 4 2100GW ASSEMBLY OR...

Page 8: ...mericas 195 Internationale Blvd Glendale Heights IL 60139 630 237 5000 Toll Free Customer Service and Technical Support 800 992 4657 Toll Free Fax 888 246 5732 Binks Sales and Service www binks com WARRANTY This product is covered by Binks 1 Year Limited Warranty 77 2936R Revisions P7 Corrected Parts List P8 Updated contact information ...