External Mix Air Nozzle Application
OPERATION:
1. Connect hose as shown in diagram.
2. Fill cup with strained fluid mixed in accordance with
manufacturer’s recommendations on label of container.
3. Fasten cover securely.
4. Close air adjusting valve by turning clockwise.
5. Set air pressure at oil and water extractor (transformer)
to between 35 and 80 PSI, depending upon atomiza-
tion desired.
6. Set regulator on pressure cup to approximately 10 PSI
for enamels; 5 PSI for lacquers. (Turn knob clockwise
to increase pressure; to reduce pressure, turn knob
counter-clockwise. Always release air in cup by
momentarily opening air release valve on cover when
attempting to reduce pressure.)
7. Open air adjusting valve.
8. With trigger fully pulled back, make several fast spray
strokes against a flat surface. After adjustment of pres-
sure, proper atomization will be indicated by an even
distribution of finely divided paint particles.
Binks Model 80-228 (2 QT.)
“STEADI-GRIP” PRESSURE
CONTAINER
Replaces
Part Sheet
1619R-9
Part
Sheet
77-1619R-10
Air from Oil and
Water Extractor
(Transformer)
Fluid Pressure
Gauge
Safety Valve
(Do not tamper
with or readjust)
Fluid Pressure
Regulator
Knob
Lubricate Cup
Threads
Air
Adjusting
Valve
Fluid
Hose
Air Hose
Air Release
Valve
Air Nozzle