14
The filter cleans the compressed air from water condensate, scale, rust particles etc.
Drain off the water condensate at regular intervals and clean the sintered filter if it is dirty.
Before putting the pressure line into operation, relieve the filter regulator by fully unscrewing
the regulating screw. Thereafter rotate the regulating screw clockwise until the pressure
gauge on the filter regulator indicates the required pressure (please consider the min. and the
max. data - see section 3 Technical Data).
5.3 RINSING THE BINKS AIRLESS PUMP
Wear eye protection
Every BINKS airless pump is tested with water during final inspection and thoroughly rinsed with a
non-gumming preservative oil. With this rinsing process, it is possible that the residual moisture of
water emulsion will be left in the pump.
Before the unit is started up for the first time, a suitable solvent must be used to thoroughly rinse
out the remains of the preservative fluid and the unavoidable impurities introduced during equip-
ment assembly.
Proceed as follows:
1. Prepare the BINKS airless pump for start-up in accordance with section 5.2.
2. Close the high pressure filter relief valve.
3. Immerse the spray material pump or the suction system in the tank of solvent.
4. Insert the high pressure filter return pipe into the tank of solvent. Open the high pressure filter
relief valve.
5. Open the ball valve of the air supply and set the compressed air control valve on the pressure
regulator to approximately 1 bar. The spray material pump or the suction system now draws in
the solvent. The solvent runs back to the tank through the high pressure filter, the high pres-
sure filter relief valve and the return pipe.
6. Point the airless gun into the tank. Unlock the safety lever on the airless gun, operate the air-
less gun trigger and close the high pressure relief valve. The solvent will now flow through the
high pressure filter, the spray material line and the airless gun, back into the tank.
The time of rinsing depends on the length of the material lines and the solubility of the spray
material. We recommend a short reflush with "fresh" solvent.
7. Release the airless gun take-off.
8. Slowly increase the pressure at the compressed air control valve of the pressure reducer to
maximum working pressure (see section 3, Technical Data), while checking and testing that
all lines and screw and plug caps are tightly sealed. If there are any leaks in the system, shut
down the BINKS airless pump immediately. Only re-start the BINKS airless pump once you
have repaired the leak.
9. Reduce the pressure at the compressed air control valve of the pressure reducer again and
close the ball valve.