Field
Description
The default value is
)
.
Loopback Segment
Select whether you want to activate the loopback test for the
segment connection (segment = connection of the local end-
point to the next connection point) of the VCC or VPC.
The function is enabled with
;
.
The function is disabled by default.
Segment Send Interval Only if Loopback Segment is enabled.
Enter the time in seconds after which a loopback cell is sent.
Possible values are
to
.
The default value is
)
.
Segment Pending Re-
quests
Only if Loopback Segment is enabled.
Enter the number of directly consecutive loopback cells that
may fail to materialise before the connection is regarded as in-
terrupted ("down").
Possible values are
to
.
The default value is
)
.
Fields in the CC Activation menu.
Field
Description
Continuity Check (CC)
End-to-End
Select whether you activate the OAM-CC test for the connection
between the endpoints of the VCC or VPC.
Possible values:
•
5--6
(default value): OAM CC requests are responded to
after CC negotiation (CC activation negotiation).
•
36
: OAM CC requests are sent after CC negotiation (CC
activation negotiation).
•
9 7
: OAM CC requests are sent and answered after CC ne-
gotiation (CC activation negotiation).
•
"
: Depending on the setting in the Direction
field, OAM CC requests are either sent and/or responded to.
bintec elmeg GmbH
22 WAN
elmeg hybird 120 / hybird 130
459