Field
Description
GRE Window Adaption
Select whether the GRE Window Adaptation is to be enabled.
This adaptation only becomes necessary if you have installed
service pack 1 from Microsoft Windows XP. Since, in SP 1, Mi-
crosoft has changed the confirmation algorithm in the GRE pro-
tocol, the automatic window adaptation for GRE must be turned
off for bintec elmeg devices.
The function is enabled with
;
.
The function is enabled by default.
GRE Window Size
Enter the maximum number of GRE packets that can be sent
without confirmation.
Windows XP uses a higher initial reception window in the GRE,
which is why the maximum send window size must be adjusted
here by the GRE Window Size value. Possible values are
to
)+
.
The default value is
.
Max. incoming control
connections per re-
mote IP Address
Enter the maximum number of control connections.
23.3.3 IP Pools
The IP Pools menu displays a list of all IP pools for PPTP connections.
Your device can operate as a dynamic IP address server for PPTP connections. You can
use this function by providing one or more pools of IP addresses. These IP addresses can
be assigned to dialling-in connection partners for the duration of the connection.
Any host routes entered always have priority over IP addresses from the address pools.
This means if an incoming call has been authenticated, your device first checks whether a
host route is entered in the routing table for this caller. If not, your device can allocate an IP
address from an address pool (if available). If address pools have more than one IP ad-
dress, you cannot specify which connection partner receives which address. The ad-
dresses are initially assigned in order. If a new dial-in takes place within an interval of one
hour, an attempt is made to allocate the same IP address assigned to this partner the last
time.
Choose theAdd button to set up new IP pools.
bintec elmeg GmbH
23 VPN
elmeg hybird 120 / hybird 130
519