08 - THREE DIFFERENT FORMS OF CLEANING

09 - MAINTENANCE AND SUGGESTIONS

a)   “LIGHT” DIRT:
 

To remove “light” dirt (dust, saliva, etc.) it is not necessary to use detergents or chemicals, 
nor the heating system, only water is enough. 

b)  “MEDIUM” DIRT: 
 

To remove “medium” dirt (fat, blood, etc.) it is recommended to use of the heating system 
for better process efficiency. 

 

Note: If you want to reduce the time to heat water, you can add a little warm water, but 
never put boiling water since it will cause thermal shock and damage to the crystals.

c)  “HEAVY” DIRT:
 

To remove “heavy” dirt (very oily parts) it is recommended the use of heating system with a 
crust removing cleaning solution (household detergents, enzymatic, crust removing, etc.).

NOTE:  During  cleaning,  the  dirt  appears  as  resembling  “smoke”,  while  the 
water gets dirty. When the aspect of “smoke” does not appear, the item is clean 
and does not need a longer time. If the water is dirty, replace the water and start 
a new cycle.

!

•  Clean the vat regularly and frequently replace the cleaning solution to increase the efficiency, it 

is recommended the use of an enzymatic crust removing solution for better efficiency. Each 
exchange of fluid should be done at one cycle of 180 seconds (without instruments) in order to 
eliminate possible air bubbles (degassing process) that may compromise the effectiveness in 
the first wash;

•  The use of liquids with high concentration acid and / or  temperature  above  65  °  C  is  not 

advisable;

•  Always use accessories as basket or beaker, so that the  material does not remain on the bottom 

of the vat; 

•  Maintain  the  machine  off  when  replenishing  with  liquids  and  especially  when  it  is  not  in 

operation;

•  Avoid  dirt  to  settle  on  the  bottom  of  the  vat  over  an  extended  period  of  time. This  dirt  may 

decrease the ultrasonic cavitation effect. Do not use the Ultrasound vat in places with much 
dust. The accumulation of dust can interfere with the normal operation of the equipment; 

•  Avoid the equipment to remain with water for long periods when it is not in use;

•  Do not restrict ventilation. It should be appropriate in order to avoid overheating;

•  The ultrasonic cleaning is very effective for hard materials, but less effective for soft and porous 

materials. The harder the surface, the greater the efficiency of the ultrasonic cleaning.

- 05 -

Summary of Contents for BioWash

Page 1: ...USER s MANUAL Ultrasonic Washer Mod STD BioWash...

Page 2: ...PACKAGE CONTENTS 02 05 INSTALLATION AND CARE 02 06 DIRECT AND INDIRECT USAGE METHODS 03 07 INSTRUCTIONS FOR USE 03 08 THREE DIFFERENT FORMS OF CLEANING 05 09 MAINTENANCE AND SUGGESTIONS 05 10 TECHNICA...

Page 3: ...tion The ultrasonic method is faster and more efficient than the manual method in the following aspects Speed and optimization in the process of cleaning instruments used routinely in offices clinics...

Page 4: ...horten the life of the equipment Keep the unit unplugged from the power supply while filling with water Do not exceed the maximum level of filling MAX in the vat To avoid electrical shock never touch...

Page 5: ...t can be filled with different crust removing solutions Another advantage of the indirect method is that the containers becker can be autoclaved to avoid cross contamination of prosthetic parts applia...

Page 6: ...is machine is equipped with a protection circuit against overheating When the temperature limit is reached the LED indicator Overload protection LED located right panel will be red interrupting the cl...

Page 7: ...iciency it is recommended the use of an enzymatic crust removing solution for better efficiency Each exchange of fluid should be done at one cycle of 180 seconds without instruments in order to elimin...

Page 8: ...W AC 100 127 160 W Ultrasonic Frequency 42 000 Hz Vat Material Stainless Steel S U S 304 Plastic material of cabinet ABS 757 Vat Size 264 X 164 X 80 mm LXAXP 10 40 X 6 46 X 3 15 inches Vat Capacity 26...

Page 9: ...ng ring 08 Instrument holder basket 09 Stainless steel vat 10 Vat bracket 11 Lead fixer 1 12 Lead fixer 2 13 Heater 14 Heater cover guide 15 Fan fastener 16 Fan 17 Shell 18 Power supply circuit board...

Page 10: ...art com br This manual contains all the necessary information about the operation of BioWash Standard and its uses BIO ART does not guarantee the equipment for failures caused by misuse so we emphasiz...

Page 11: ...Rua Teot nio Vilela 120 Jd Tangar CEP 13568 000 S o Carlos SP Brasil Tel 55 16 3371 6502 Fax 55 16 3372 5953 Home Page www bioart com br E mail bioart bioart com br CMAN1219 March 2012...

Reviews: