35
Elsa Model:
D14
D15
Model Paula:
-
Place the baffle plate on the lateral and rear vermiculites parts.
-
You must insert it turned in order to pass it through the door of the stove. (
see drawing D15
)
7. VENTILATION SYSTEM
The Paula model incorporate a convection turbine as standard, the operation of this turbine is in line with the
working power of the model, so that with the stove switched on, the turbine will always remain in operation. The model Elsa has the possibility
to active or deactivate the convection turbine of the stove. By using the remote control, you can activate the operation of the turbine. In this
way, the stove will heat the air through the own radiation of the stove and the forced convection of the turbine.
In case you choose to deactivate the operation of the turbine, the heating of the air will be generated by the radiation of the stove and, in this
case, by natural convection.
In order to active or deactive the operation of the turbine, check section 10.4.3.1 of this manual “power”.
8. SERVICING AND CARE
The maintenance operations guarantee a proper working of the product over its lifetime. Not making these maintenance operations will affect
the security of the product.
D16
8.1
BURNER CLEANING
On the other hand, in the model Elsa, the burner cleaning must be made daily
(
see drawing D16
).
•
Remove the burner from its place and clean the holes.
•
Use a vacuum to get rid of the ashes in the burner. You can buy a
Bronpi vacuum-cleaner in the same Bronpi distributor where you bought
your stove.
D17
In the Paula model, the burner is cleaned periodically and
automatically (cleaning system registered by Bronpi Calefacción),
but at least every 10 days, it is advisable to do a manual cleaning
of the burner, for this (
see drawing D17
):
•
Vacuum the ash deposited in the burner. You can purchase
a Bronpi vacuum cleaner in the same Bronpi dealer where you
bought your stove.
•
Check and if necessary clean the holes in the base of the
burner so that they are not blocked. This would make difficult a
good combustion.
EN
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
ELSA AND PAULA
Summary of Contents for ELSA Y PAULA
Page 28: ...27 ES INSTRUCCIONES DE INSTALACIÓN USO Y MANTENIMIENTO ELSA Y PAULA ...
Page 54: ...53 EN INSTALLATION OPERATING AND SERVICING INSTRUCTIONS ELSA AND PAULA ...
Page 82: ...81 FR INSTRUCTIONS D INSTALLATION D UTILISATION ET D ENTRETIEN ELSA ET PAULA ...
Page 108: ...107 PT INSTRUÇÕES DE INSTALAÇÃO USO E MANUTENÇÃO ELSA E PAULA ...
Page 109: ...108 PT INSTRUÇÕES DE INSTALAÇÃO USO E MANUTENÇÃO ELSA E PAULA ...
Page 135: ...134 IT ISTRUZIONI DI INSTALLAZIONE USO E MANUTENZIONE ELSA E PAULA ...
Page 143: ...142 13 2 PAULA 1507 519 196 269 203 197 9 4 553 519 197 283 40 8 0 1507 203 197 9 4 519 FT ...
Page 152: ...NOTAS NOTES NOTES ANOTAÇÕES ANNOTAZIONI ...