39
The following table shows the meaning of the different leds of the display of the stove. The lighting of the leds indicates the activation of the
corresponding device according to the following list:
LED
FUNCTION
L1
Led On: heating fan activated
L2
Led On: auger activated
L3
Led On: ignition resistor activated
L4
Led On: thermostat temperature reached
L5
S
Led On: daily programming
L6
G
Led On: weekly programming
L7
W
Led On: weekend programming
9.3.
USER MENU
9.3.1.
STOVE STATE
When the stove is switched on, by pressing key P1 of the display, it is possible to access the following options that give us some technical
information of the stove. The lower display shows the information (tA, tF, FL, UF, etc) and the upper display shows the value (ºC, rpm, sec,
etc.).
INFORMATION
VALUE
tA
Room temperature of the base (ºC)
tF
Smoke temperature (ºC)
Tr
Remote air temperature (ºC)
FL
Flow speed of the primary air (cm/sec)
UF
Smoke extractor speed (rpm)
Co
Auger activation time (sec)
St
Remaining time until maintenance service 1(h)
St2
Remaining time until maintenance service 2 (h)
FC
Code and firmware version.
30
LoAd
GS
W
ESC
D34
9.3.2.
PELLET MANUAL LOAD
If during the operation of the stove, it runs out of fuel, in order to avoid any problem
during the next ignition, it is possible to carry out a preload of pellet of the auger
during a maximum time of 300 seconds when the stove is switched off and cold
and the door is closed. A long press of key P3 starts the preload. The lower display
will show the message “LoAd”, and the upper display will show the seconds
elapsed. In order to interrupt the load, press any key.
Before proceeding with a new ignition of the stove, do not forget to empty the
burner in order to avoid a dangerous situation (
see drawing D34
).
0
peLL
GS
W
ESC
D35
9.3.3.
PELLET LOAD CORRECTION
In order to access to
the modification mode, it is necessary to press for a while key P2 and, later, press
again P2 for a while. The lower display shows the message “Pell” and the upper
display shows the value introduced. By using keys P2 and P4, it is possible to
increase or decrease the value introduced. The original value introduced is 0 and it
goes from -7 ... to ...+7. Note that each numerical value modified is equal to modify
proportionally in all the powers a 2% of the load time value (in seconds) set for the
auger. After 5 seconds, the new value will be saved and the display will return to
the normal state.
Consider that a higher pellet load means a higher thermal power of the stove and,
therefore, a higher fuel consumption. If you observe that the stove is not burning
properly or the mix air/fuel is not appropriate, try to modify the fuel load (
see
drawing D35
).
EN
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
ELSA AND PAULA
Summary of Contents for ELSA Y PAULA
Page 28: ...27 ES INSTRUCCIONES DE INSTALACIÓN USO Y MANTENIMIENTO ELSA Y PAULA ...
Page 54: ...53 EN INSTALLATION OPERATING AND SERVICING INSTRUCTIONS ELSA AND PAULA ...
Page 82: ...81 FR INSTRUCTIONS D INSTALLATION D UTILISATION ET D ENTRETIEN ELSA ET PAULA ...
Page 108: ...107 PT INSTRUÇÕES DE INSTALAÇÃO USO E MANUTENÇÃO ELSA E PAULA ...
Page 109: ...108 PT INSTRUÇÕES DE INSTALAÇÃO USO E MANUTENÇÃO ELSA E PAULA ...
Page 135: ...134 IT ISTRUZIONI DI INSTALLAZIONE USO E MANUTENZIONE ELSA E PAULA ...
Page 143: ...142 13 2 PAULA 1507 519 196 269 203 197 9 4 553 519 197 283 40 8 0 1507 203 197 9 4 519 FT ...
Page 152: ...NOTAS NOTES NOTES ANOTAÇÕES ANNOTAZIONI ...