42
-
Step 2
0 0
:
0 0
GS
W
ESC
D45
0 7
:
5 9
U
GS
W
ESC
D46
1 3
:
0 0
3
GS
W
ESC
D47
9.4.
USER MODE
The normal operation of the display/receiver is described below.
Before switching on the display, the stove state is showed in
drawing D47
. It only
shows the room temperature and the current time.
9.4.1.
IGNITION OF THE STOVE
In order to ignite the stove, simply press the key P1 during a few seconds. Firstly, the stove carries out an initial check-up and continues the
ignition process. After this, the display shows different steps of the ignition process (2, 3 and 5) (
see drawings D48, D49,D50 and D51
).
The maximum duration of the ignition phase is 20 minutes. If after this time there is not flame, the stove will automatically activate the alarm
state and the display will show the alarm message “Er12”.
GS
W
ESC
GS
W
ESC
GS
W
ESC
GS
W
ESC
D48
D49
D50
D51
1 3
:
0 0
3 0
GS
W
ESC
D52
9.4.2.
STOVE IN OPERATION
Once certain smoke temperature has been reached, the hot air fan starts working.
Once the ignition phase has been finished properly, the stove enters into “Work”
mode which represents the normal operating mode (
see drawing D52
).
The display shows the time, the working power and the room temperature.
1 3
:
0 0
GS
W
ESC
D53
9.4.3.
ADJUSTMENT OF THE ROOM TEMPERATURE
Press key P2 or P4 and the display D4 will start flashing. By pressing keys P2 or
P4, it is possible to select the temperature desired for the room (
see drawing D53
).
After 5 seconds, the new value will be saved and the display will return to the
normal state.
EN
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
ELSA AND PAULA
Summary of Contents for ELSA Y PAULA
Page 28: ...27 ES INSTRUCCIONES DE INSTALACIÓN USO Y MANTENIMIENTO ELSA Y PAULA ...
Page 54: ...53 EN INSTALLATION OPERATING AND SERVICING INSTRUCTIONS ELSA AND PAULA ...
Page 82: ...81 FR INSTRUCTIONS D INSTALLATION D UTILISATION ET D ENTRETIEN ELSA ET PAULA ...
Page 108: ...107 PT INSTRUÇÕES DE INSTALAÇÃO USO E MANUTENÇÃO ELSA E PAULA ...
Page 109: ...108 PT INSTRUÇÕES DE INSTALAÇÃO USO E MANUTENÇÃO ELSA E PAULA ...
Page 135: ...134 IT ISTRUZIONI DI INSTALLAZIONE USO E MANUTENZIONE ELSA E PAULA ...
Page 143: ...142 13 2 PAULA 1507 519 196 269 203 197 9 4 553 519 197 283 40 8 0 1507 203 197 9 4 519 FT ...
Page 152: ...NOTAS NOTES NOTES ANOTAÇÕES ANNOTAZIONI ...