Section 2b – 

INSTALLATION

 

 

Control Box Connections 

Electrical Connections 

BIO-LAB recommends that a licensed electrician or certified electrical contractor perform the electrical connections. 

 

DANGER: ensure that the electrical panel or filter pump circuit breaker is turned OFF before wiring this unit.   

Your 

Pool Pilot

™ 

Soft Touch

 Control Box comes pre-wired from the factory for 230VAC (1.5 amps max draw) and can also operate 

on 115 VAC, (3.0 amps max draw) at 50/60Hz.  1.8m (6ft.) of AC lead wires are provided with the unit and are located on the bottom 
base plate of the control box along with the Cell, Tri-Sensor and optional ORP Interface connections. 

Converting to 115VAC

 is accomplished by accessing the circuit board, rewiring, and attaching the included jumper as shown below.  

Remove the cover (see page 10) to access and ensure that the Jumper Connections on the circuit board marked “TRANSFORMER 
PRIMARY” are matched to the LINE IN voltage.  Follow all state/local codes for electrical installations. 

 

 

 

An additional jumper is

 

  

Power Circuit Board 

provided with your 

 

 

Installation Kit for 115VAC. 

Transformer

 

 

 

 

  

Location of the

  

 

  

  

Input Jumper Connections

 

 

 

 

 

 

 

 

 

   TRANSFORMER PRIMARY 

   TRANSFORMER PRIMARY 

 

 

 

 

 

   230 VAC 

115 VAC 

TAB 7

TAB 9

TAB 8

TAB 4

TAB 6

TAB 10

TAB 3

TAB 5

230VAC

TAB 7 

TAB 9 

TAB 5 

TAB 8

TAB 4

TAB 6

TAB 10

TAB 3 

115VAC

 

115VAC 

 

 

  INNER CONTROL PANEL   

FACTORY SETTING  

WIRING DIAGRAM 

 
  Top terminals factory wired – do not disturb. 

 

    AC to PCB 

Bonding 

6-pin Tri-sensor 

 

 

Lug   

  connector 

 

 

  

 

  

    Ground   

                      Conduit 

       Lugs   

    

connector 

 

 

    

 

 provided 

 

   (Gr/Yel) (Br) (Bl) 

    

 

2-pin ORP 

Cell Cord 

 

AC 

Line In

 

Plug

 

Plug

#1 

#6 

#5 

#4 

#3 

#2 

   

 

     

 

 

Connector 

Connectors 

 

Pool Pilot AC Line IN

 

    

 

CONTROL BOX BASE PLATE

 

 

 

 

 

AC LINE IN 

(Wiring diagram also located on inside of cover)

For 230 VAC

; Brown (Br) = Line 1, Blue (Bl) = Line 2, Green w/Yellow Tracer (Gr/Yel) = Earth Ground 

For 115 VAC

; Brown (Br) = Line, Blue (Bl) = Neutral, Green w/Yellow tracer (Gr/Yel) = Earth Ground 

The AC Line IN wiring is pre-set for connection to the 

LINE SIDE

 of your time clock, electronic controller switch or relay to work 

in conjunction with your circulation pump.   

 
Cell Cord

.

  Each Cell Cord contains (2) Banana Plugs that attach to the (2) Banana Jacks on the bottom of the Control Box.  

Polarity does not matter.  The other end of the cell cord has a three-position plug that connects to the cell in any direction.  See page 
11 for service instructions. 

 
Tri-Sensor Cord

.

  The Tri-Sensor Cord connects to the keyed 6-pin harness on the Control Box Base Plate.  The opposite end of 

the cord connects to the Tri-Sensor Assembly with a locking ring quick connect.  Align the grove and keyway on the connector and 
twist the locking ring to ensure a proper connection.  Refer to the instructions on pages 10 & 12 for diagrams and additional 
instructions. 

 
ORP Connection

.  

When an ORP Chemical Controller is interfaced to your 

Pool Pilot

™ 

Soft Touch

, the Chemical Controller 

will remotely control the SANITIZER Output.  Adjust the output level to 0% and connect the ORP controller to the 2-pin connector 
on the Control Box Base Plate.  When the ORP is activated, the output will indicate ON with the display showing 0%. 

 

WARNING: THE ORP CONNECTIONS ARE DRY CONTACT INPUTS, DO NOT ENERGIZE THESE  

INPUTS!  DAMAGE TO THE CONTROL BOX WILL OCCUR AND WILL VOID THE WARRANTY. 

 

 
 

5

Summary of Contents for 28069

Page 1: ... Controls Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE NSF50 C IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This control product is to be used only in accordance with the directions on this label It is an offense under the Pest Control Products Act to use a control product under unsafe conditions Bio ...

Page 2: ..._________________ Control Unit Control Unit Model Number ST60______________ Serial Number ____________________________ Cell Model Number RC 13 Serial Number ____________________________ Customer Assistance HOTLINE 1 800 268 6572 or 905 686 8836 FAX 905 619 8696 Manufactured for Bio Lab Canada Inc 1005 Copperstone Drive Pickering ON L1W 4A5 Pool Pilot Soft Touch by BIO LAB CANADA INC 1 ...

Page 3: ...try in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Pool Pilot Soft Touch to connect a minim...

Page 4: ... Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b Servicing ...

Page 5: ... Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 77 kg 1 68 lbs of free available chlorine day 230 VAC 1 5 AC amps RC 13 CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Lif...

Page 6: ...Gr Yel Br Bl 2 pin ORP Cell Cord AC Line In Plug Plug 1 6 5 4 3 2 Connector Connectors Pool Pilot AC Line IN CONTROL BOX BASE PLATE AC LINE IN Wiring diagram also located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre set for conn...

Page 7: ...ify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf ball in the strainer screen uni...

Page 8: ...r water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on Normal or Long is more detrimental to the life of the cell and changing the Reverse cycle is suggested The BOOST Button activates the Boost light when it is pressed once This light indicates that the ...

Page 9: ...ies TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL Pool Volume in Liters US Gallons SALT Level Before Addition 3 780 1 000 9 430 2 500 18 900 5 000 28 300 7 000 37 780 10 000 56 700 15 000 75 600 20 000 113 600 30 000 0 ppm 11 3 25 28 63...

Page 10: ...odium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name and allows the chlorine residual to last longer by protecting it from the UV degradation of the sun With low or no Cyanuric acid it is possible for the chlorine to be used up as quickly as it enters t...

Page 11: ...trol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel Circuit Board Fuse 3 Amps 250 VAC F3 Cell Fuse 20 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons mi...

Page 12: ...h a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use a non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutralized and ...

Page 13: ...l Unions and Cord ordered separately 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Cell RC 13 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately Directional Flow Indicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Direction of Water Flow Temperature Sensor Post Sal...

Page 14: ...B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calcium hardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to water chemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Cont...

Page 15: ...se of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The second value is the water temperature in degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the next the units ...

Page 16: ...READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Imported to Canada for BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 REGISTRATION NO 28069 PEST CONTROL PRODUCTS ACT MINERAL SPRINGS SOFT TOUCH MODEL ST60 Chlorine Generating Device One ST60 unit can treat a maximum of 190 000 Liters of swimming pool water Notice to User This control product is to be used only i...

Page 17: ...REGISTRATION NUMBER 28069 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device MINERAL SPRINGSModel DIGITAL 60 or MINERAL SPRINGSModel Soft Touch ST60 before using BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 MINERAL SPRINGS Cell Label for DIG ...

Page 18: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...