BLOWER INSTALLATION
Always have all utility lines and equipment marked by a locating service provider prior to performing
any work.
All electrical work must be properly performed by a qualified electrician per all applicable codes.
Failure to do so may result in severe bodily injury or death.
1.
The blower and blower housing must be
mounted on a pad to avoid settling. All
conduit/piping should pass through the pad
from below. Blower must be located above
flood levels.
2.
Secure lower blower housing to pad using 4
supplied #14 x 1½” self-tapping screws. Drill
screws directly into blower pad.
3.
Connect initial blower fittings (right).
4.
Connect airline from FAST® unit to blower outlet
using required piping. We recommend a union
be installed inside the housing on the blower
outlet piping for easy removal of blower. Keep
all debris out of airline. All connections must be
air-/watertight.
5.
Connect incoming power to the blower at the
blower junction box. Be sure to follow the
supplied wiring diagram for the voltage at your
specific location. All blowers are dual voltage
and must be connected according to the proper
diagram. Blower diagrams can be found on the
blower’s shipping box and at the end of this
manual.