VaDia Startup Guide v1.1 

24/25 

www.biocontrol.no/vadia 

11.  VADIA LIMITED WARRANTY & LIABILITY LIMITATIONS 

This product is limited warranted against defects in materials and workmanship 
for twelve (12) months from the original date of purchase. The battery carries a 
limited warranty of 6 months from the manufacturing date. The battery must be 
properly charged according to the instructions in this manual. 
If notice is received of such defects during the limited warranty period, the 
proven defective product(s) will either be repaired or replaced, at the 
manufacturer’s option. Replacement products may be either new or like new. 
The manufacturer does not warrant that the operation of the products will be 
uninterrupted or error free. 
 
Limited warranty does not apply to defects resulting from (1) improper or 
inadequate maintenance or calibration, (2) software, interfacing, parts or 
supplies not supplied by the manufacturer, (3) unauthorized modification or 
misuse, (4) operation outside of the published environmental specifications, or 
(5) physical damage due to external causes, including accident, abuse, misuse 
or problems with electrical power. 
The product must be adequately sealed against water or moist ingression 
since damage to PCB and vacuum sensors due to water, moist or milk is not 
covered by this limited warranty. 
 
To the extent allowed by local law, the above limited warranties are exclusive 
and no other warranty or condition, whether written or oral, is expressed or 
implied, specifically disclaiming and implied warranties or conditions of 
merchantability, satisfactory quality, and fitness for a particular purpose. 
 
To the extent allowed by local law, the remedies in this limited warranty 
statement are the customer’s sole and exclusive remedies. Except as indicated 
above, in no event will the manufacturer or its distributors be liable for loss of 
data or for direct, special, incidental, consequential (including lost profit or 
data), or other damage, whether based in contract, tort or otherwise.  

Summary of Contents for VaDia

Page 1: ...short for Vacuum Diagnostics and illustrates the value of this hi tech instrument for technicians advisors and other professionals in the dairy industry that want to understand and manage udder healt...

Page 2: ...nnecting the vacuum sensors 10 7 5 Start logging 12 7 6 Saving the log file on the PC 13 7 7 Battery Capacity Indication 14 7 8 Work with the log files 14 8 ADVANCED USERS 15 8 1 Make a Bluetooth conn...

Page 3: ...measurement and concentrate on observing milking routines The logged data can be analyzed after milking with VaDia Viewer an easy to use PC tool to view vacuum details and generate summary reports A B...

Page 4: ...aping VaDia to a milking cluster In applications where water contact is very likely e g robots the VaDia should also be put in a plastic bag Failing to take these preventive actions will allow water a...

Page 5: ...eck your package for the following items Please contact your reseller if anything is missing or different 1 VaDia with rechargeable battery 2 Battery charger 3 USB cable 4 Startup Guide 5 Software CD...

Page 6: ...Startup Guide v1 1 6 25 www biocontrol no vadia 5 HARDWARE OVERVIEW 1 Vacuum sensors 2 USB cap 3 Status LED 4 Rechargeable battery 5 Battery cover 6 Overheating sensor 7 Battery type selector 1 2 3 4...

Page 7: ...y light After this 4 green flashes every 15 seconds to indicate idle status waiting See table in 6 6 for more details on this status indication Charge the battery and check the battery connection if t...

Page 8: ...s LED 3 3 shows the current status of the VaDia Status Function Off Battery discharged Red short flash once per s Battery too low to start Green 4 flashes once per 15 s Green 1 flash once per 15 s Gre...

Page 9: ...l to the PC clock and the mode should be LOG The battery voltage should be 1 3 V or higher Example 1 Example 2 In the above Example 1 the battery is too low 1 16V There will be a risk of power loss du...

Page 10: ...ensors When the VaDia is attached to the teat cup the vacuum sensors 5 1 must be connected to the vacuum sources by means of the supplied silicon tube 4 7 and straw tube 4 8 Slide the straw tube over...

Page 11: ...of the needle rod covered by the straw tube Find the test point and use the tool to make a hole and pierce both the tool and the straw tube through the hole The tool with the tube pierces trough the...

Page 12: ...onnect the vacuum sensors After attachment recheck that the VaDia is running and ready for logging Status LED 3 3 flashes green once per 15 seconds Autostart Every 15 seconds when the green LED flashe...

Page 13: ...in different states the log file can be stored regardless of the mode If a log is present first select the log format For VaDia Viewer select Vadim vd5 For MT2000 select MT2000 Note VaDia Viewer is su...

Page 14: ...iles or MT2000 for the mmd and mmt files These programs are not covered in this Startup Guide refer to the corresponding program manuals for this Here the battery capacity indication is 2500 mAh This...

Page 15: ...VaDia start a log session in Bluetooth mode chapter 7 2 On PC add a Bluetooth device to your PC search for device enter PIN code and connect Win XP and Win 7 have slightly different working methods Wi...

Page 16: ...VaDia Startup Guide v1 1 16 25 www biocontrol no vadia Select the Bluetooth device here Box 1 Enter the passkey 1111 Wait while Bluetooth is installed Note the Outgoing COM port here 71 Ready...

Page 17: ...ces and Printers and select Add a device Enter passkey 1111 when requested and wait for the message this device has been succesfully added to this computer Go to Start Control Panel Hardware and Sound...

Page 18: ...up VaDia Setup Change COM port setting here COM71 The VaDia must be connected to a vacuum source to show data in streaming mode If no vacuum is attached the graph will stay on zero Suck the vacuum inl...

Page 19: ...s to be disconnected and then reconnected to activate the new ID The Found New Hardware message will appear Since the driver already exists on the PC the drivers will install automatically If the conn...

Page 20: ...s after the zero calibration The displayed counter values sensor tara and calib are for service purposes and can be ignored Follow the same procedure to calibrate for 40 kPa The individual sensors can...

Page 21: ...hut down any running programs of the VaDia Manager and connect the VaDia to a USB port of the computer Only one VaDia can be connected to the computer when uploading new firmware Start the program VaD...

Page 22: ...uetooth Class 1 for Streaming mode Battery Rechargeable or replaceable standard format AA Weight 80g with battery Log transfer speed Approx 25 sec per hour of log Casing Splash proof but care must be...

Page 23: ...name VaDia Part Nr 0800 6498 00 Options Bluetooth complies with requirements of the following directives EMC EN 300 328 V1 7 1 EN 301 489 01 V1 8 1 EN 301 489 17 V2 1 1 Reference NEMKO Report No 174...

Page 24: ...by the manufacturer 3 unauthorized modification or misuse 4 operation outside of the published environmental specifications or 5 physical damage due to external causes including accident abuse misuse...

Page 25: ...TROL CUSTOMERS IN THE EUROPEAN UNION To recycle BioControl products WEEE Waste Electrical and Electronic Equipment products that run on electrical power please ask for instructions at productrecycling...

Reviews: