| instructions for use, maintenance and installation |
10
ATTENTION
Installation of draught closing valves is prohibited!
Flue connection Ø 80 mm from pellet boiler to flue pipe should be:
•
no more than 5 m long (in case of longer connection, dimension of connection pipe
must increase to Ø 130 mm);
•
each 90° joint requires a 1 m shorter flue connection;
•
each joint must be fitted with doors for cleaning;
•
connections between pipes must be sealed.
ATTENTION
If there is too much resistance in extraction system (many joints, improper end fitting,
bottlenecks etc.), extraction of smoke gases is not provided for. Therefore, connection pipes
and joints must be increased to a greater dimension – Ø 130 mm. If the flue does not ensure
appropriate extraction of smoke gases, it can also come do improper operation and,
consequently, to alarm from boiler Biodom C15. It is advisable that the flue is inspected by
an expert before installing boiler Biodom C15.
Smoke gases extraction system from pellet boiler functions on the basis of negative pressure in the
boiler and barely perceivable pressure in flue connection pipe Ø 80 mm. It is very important that the
smoke gases extraction is sealed.
Layout and structure of the space, where the flue is installed, needs to be analyzed. If it passes
through walls and/or roof, it must be properly installed in accordance with fire prevention safety
standards.
Ensure that there is enough air for proper combustion in the space, where the pellet boiler is
installed. If boiler Biodom C15 lacks oxygen/air, the boiler displays an alarm. External supply or intake
of external air requires a pipe with a diameter of at least 110 mm with maximum length of 10 m. Each
90° joint requires a deduction of 1 m in line length. If the air supply is longer, diameter of air intake
pipe must be increased.
In case of a grid on the facade, draught opening must be 100 cm² or larger.
The device operates at 220 V – 50 Hz. Make sure that the electrical cables are not laid under the
boiler, that they are far away from hot surfaces and that they do not touch sharp parts, which could
damage them. If the pellet boiler is under electrical overload, life expectancy of electrical component
greatly reduces.