9.2.
BOILER SHUTDOWN
When pressing and holding the
ON/OFF button
for more than half a second (during boiler operation),
the display shows
ON
, and the boiler starts shutdown sequence once the button is released. Dosing
screw turns off and the display indicates
STOP FIRE
. Fans operate at high speed to prevent excessive
increase of water temperature in the boiler. When the boiler cools down under set temperature, fans
switch to maximum speed and blow out the last parts from the firebox. Display indicates
OFF.
9.3.
BOILER ACTIVATION
When pressing and holding the
ON/OFF button
for more than half a second (boiler at standstill), the
display shows
OFF
, and the boiler begins activation sequence once the button is release. Display
indicates
TESTFIRE
. Fans operate at high speed to clean the firebox. Dosing screw is at standstill,
spark plug is heating.
If the firebox temperature is low, sequence
HEAT UP
begins, where pellets are dosed quickly and fans
stand still. Then sequences
Fuel IGNI
and
TEST IGNI
start, until the boiler reaches conditions for
transition to burning phase (
BURN
).
ATTENTION
By pressing and holding
MENU button
for 2 seconds (release the button when tH20 displays),
the display indicates current water temperature in the boiler. By pressing
button UP
or
button
DOWN
you select display of other temperatures and fan status .
9.4.
TIME PROGRAMME SETTING
Press and hold (until
TEN
displays)
MENU button
to access time programme menu.
By setting ON or OFF, the time programme activates or deactivates.
Accurate time and current day of the week (1 is Monday etc.) must be set and then, 6 programme
periods and temperatures must be programmed.
Each of 6 time period is determined by start (P1a – programme 1 start time) and end time (P1d –
programme 1 end time). In this period, the boiler is active and operates by maintaining water
temperature in the boiler (P1t).
Then select up to 3 time periods for each day of the week.
Example (Tuesday): upper display shows DAY2, and lower P1, P3 and P6, which means that the boiler
will be active on Tuesday in periods, programmed with programmes P1, P3 and P6.