Biodom C15
Biodom C15
Biodom C15
Biodom C15 |
|
|
| instructions for use, maintenance and installation |
9
Figure 1: Minimum distance of boiler from boiler room walls
If the pellet boiler is installed in a boiler room, where there are other devices, which drain air (other
boiler, various suction fans etc.), make sure that the volume of air intake is sufficient for safe
operation of combustion device.
If the smoke duct passes through a ceiling, it must be properly insulated using diaphragm of non-
combustible insulation material.
When the pellet boiler is placed, it must be levelled with support feet (horizontal positioning).
ATTENTION
Smoke gas discharge MUST NOT BE CONNECTED TO:
•
flue pipe, used by other combustion devices (boilers, stoves, fireplaces etc.);
•
air extraction systems (hoods, air extraction fans etc.).
Flue pipe