BioLite
2
BioLite
3
Operating Instructions and Parts Manual (Automatic)
Surface Mounted High Speed Hand Dryer
General Safety Information
WARNING
This product is intended for installation by a
qualified service person. Use AWAG No.16 solid
conductor for wiring.
Failure to properly ground unit could result in
electrical shock and/or death.
Disconnect power at the service breaker before
installing or servicing.
NOT FOR HOUSEHOLD USE - MAY CAUSE BURNS
“IMPROPRE A L’USAGE DOMESTIQUE - PUET
OCCASIONNER.”
All units must be supplied with a 3-wire service. The
ground wire must be connected with the dryers
back plate.
NOTE: Do not install dryer over wash basin.
Type Y attachment
If the power supply cord is damaged, it must be
replaced by the manufacturer or its service agent or a
similar qualified person in order to avoid a hazard.
Means for disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules.
Installation
Installation must be carried out by a qualified elec-
trician
1. Make sure power supply breaker is switched off.
Installation must be carried out in accordance with the
current edition of the local wiring regulations code
having jurisdiction. Installation should be performed
only by a qualified electrician.
2. Place template against wall at desired height
(see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at
knockout (KO) location.
NOTE: For two or more dryers, dryers should be no
closer than 24 inches (610 mm) on centre.
3. Remove and retain 2 cover screws and cover.
4. Connect supply wires to terminal block where
indicated and connect ground wire to baseplate with
ground screw.
Connections:
a. Connect the live wire (coloured red or brown) to
the terminal block marked “L”.
b. Connect the neutral wire (coloured black or blue)
to the terminal block marked “N”.
c. Connect the ground wire (coloured green or green
and yellow) to the green screw marked “ ”.
Note that the colour of live and neutral wires depends
on voltage of supply service.
5. Replace cover. Do not over-tighten screws.