Biometrics Direct – BioCert FS-100 Door Lock
Page 10
Registering Alternate Masters
The BioCert FS-100 Door Lock enables you to register two Alternate
Masters, beyond the Primary Master.
Master 2 = 0202
Master 3 = 0303
Once registered as a master (either Primary or Alternate), you will be
given the authorization to register and delete other users.
Step
Description
1
Remove the two screws on the bottom of the face cover to reveal
the keypad.
2
Press ‘ADD Button’
3
The Green and Yellow lights will light simultaneously.
4
The primary master is to place his/her fingerprint on the scanning
platform to authorize additional users.
5
The Green Light will stay lit waiting for a PIN code for the new user.
6
Enter a 2 digit pin code twice. (for master 2 user 0202, for master 3
use 0303).
7
The Green and Yellow lights will light simultaneously.
8
Place the new Master’s fingerprint on the scanner to scan the first
template.
9
When the scanner light goes dark, remove your finger from the
scanner.
10
The Green and Yellow lights will light simultaneously.
11
Place the SAME fingerprint on the scanner to scan the second
template.
12
The system will beep when the second template is registered.
13
The FDS-100 will now compare the two templates registered and
save the Alternate Masters template to memory.
14
The Green light will blink three times to let you know that the
Primary Master is now registered.
15
You may now replace the face cover or register additional masters
or authorized users
▲
If the registration is accepted by the system, you will hear the beep
sound with the
green
LED blinking. If failed, the
red
LED will blink and the
system will beep four times rapidly. That means you need to repeat the
steps outlined above.
▲
Masters’ ID number must always be ‘01’, ‘02’ and ‘03’. For
programming purposes, these are entered as 0101, 0202, and 0303