Troubleshooting for your Cool Mist Humidifier

Trouble

• Power light not illuminated.

• “Empty/Refill” light 

illuminated. 

• Mist output minimal to

none.

• Water leaks from water 

reservoir.

• Water Filter turns brown.

• Film on water reservoir.

• Water cloudy.

• Humidistat cycles on/off.

• Very tight reservoir cap.

Probable Cause

Unit not plugged in. 

Power failure.

Water reservoir empty.

Scale build-up in 
base.

Scale build up on float

Filter has not 
absorbed water.

Mineral buildup in base.

Humidistat is set too low.

Wick Filter needs 
to be replaced.

Normal operation.

Rubber O-ring is missing
or improperly placed.

Reservoir Cap not 
tight enough.

Your filter needs  
to be changed.

In areas with particular 
hard water your wick 
filter will need to be 
changed frequently.

Mineral deposits cause 
film on tank to build up.

Filter needs  
to be replaced.

Using warm water
to refill reservoir.

Humidifier is reacting 
to room humidity level.

Over tightened.

Solution

Plug in unit.

Check circuit breaker or 
outlet.

Refill Water reservoir.

✔ 

Remove base and flush 
out residue.

Clean float tubes and 
float.

✔ 

Wait 15 minutes before 
starting humidifier.

Regular cleaning of tray
after each use will help
keep the unit functioning
properly.

Set the humidistat to 
high.

✔ 

Replace your wick filter 
(WF2630) by calling 
1-800-253-2764, or visit 
www.bionaire.com.

Mist is invisible.

Check to see if inlet or 
outlet grills are blocked

✔ 

Remove reservoir 
cap then replace 
or reposition ring.

Tighten the 
reservoir cap.

✔ 

Replace your wick filter 
(WF2630) by calling 
1-800-253-2764, or visit 
www.bionaire.com.

Use Clean Away Solution
(DMS216), to order call 
1-800-253-2764, or visit
www.bionaire.com.

Replace your wick filter
(WF2630) by calling 
1-800-253-2764, or visit
www.bionaire.com.

Refill using cool water.

Set the humidistat to a
higher or lower setting.

Add liquid soap or 
pertroeum jelly to cap 
gasket to ease opening.

Summary of Contents for COOL MOISTURE BCM4505

Page 1: ...BCM4510 Read instructions before operating Retain for future reference Instruction Leaflet INFO LINE If after having read this leaflet you have any questions or comments on your humidifier call 1 800...

Page 2: ...ifier on a firm flat level surface 4 from wall A waterproof mat or pad is recommended for under the humidifier NEVER place it on a rug or carpet or on a finished floor that may be damaged by exposure...

Page 3: ...ifier on a firm flat level surface 4 from wall A waterproof mat or pad is recommended for under the humidifier NEVER place it on a rug or carpet or on a finished floor that may be damaged by exposure...

Page 4: ...mediately begin to empty into the base mode refill humidistat power Humidifier Housing Float underneath Moisture Outlet Control Panel Wick Filter Base Figure 1 Housing Support Handle Reservoir Handle...

Page 5: ...mediately begin to empty into the base mode refill humidistat power Humidifier Housing Float underneath Moisture Outlet Control Panel Wick Filter Base Figure 1 Housing Support Handle Reservoir Handle...

Page 6: ...m humidity level by pressing the or buttons in increments of 5 If you scroll past the maximum setting of 65 the display will automatically loop back to 30 3 Now the desired room humidity level is set...

Page 7: ...m humidity level by pressing the or buttons in increments of 5 If you scroll past the maximum setting of 65 the display will automatically loop back to 30 3 Now the desired room humidity level is set...

Page 8: ...ir with cool water replace the humidifier housing and the water reservoir Repeat Operating Instructions STORAGE INSTRUCTIONS If your humidifier will not be in use for two days or more or at the end of...

Page 9: ...ir with cool water replace the humidifier housing and the water reservoir Repeat Operating Instructions STORAGE INSTRUCTIONS If your humidifier will not be in use for two days or more or at the end of...

Page 10: ...sing warm water to refill reservoir Humidifier is reacting to room humidity level Over tightened Solution Plug in unit Check circuit breaker or outlet Refill Water reservoir Remove base and flush out...

Page 11: ...sing warm water to refill reservoir Humidifier is reacting to room humidity level Over tightened Solution Plug in unit Check circuit breaker or outlet Refill Water reservoir Remove base and flush out...

Reviews: