Thank you for purchasing PalmCare plus(Handheld Pulse Oximeter). 

For safe and efficient operation, please read the manual to learn about the functions of the product 

before use.

 Please keep this manual nearby to assist you with operating the functions of the product.

The product should be used under the supervision of a medical- related certified professional.

The product is used for examining patient’s abnormal condition. For the safety of the patient, only the 

components or the accessories recommended by our company should be used.

If you connect any accessories to the product that is not specified in the manual, please be sure to 

notify our company or an agency authorized to distribute our products.

For various services and product information, please feel free to contact our salesperson at the 

following number.

For any questions about use or setup of the product, please contact the following number.

Technical Support

                    BIONICS Co,.Ltd.  

       Tel: +82-31-696-4899 

  For reporting defects or abnormalities, please note the model name, product serial number, 

purchasing date, and abnormal points before contacting us.

The product you have purchased comes with a 1-year warranty from the purchasing date covering 

inferior materials and the manufacturing process. For the disposable products, a warranty is given 

for 6 months from the purchasing date or 6 months from its first use covering inferior materials and 

the manufacturing process. This warranty cannot be applied to consumption supplies such as the 

battery, external cables, cradle and disposable accessories. 

Before Using the Product

Symbols in the Manual   4  

PalmCare plus

We are not responsible for any physical, financial and mental loss or damage and direct or indirect 

expenses caused by, or resultant from, accidental or special circumstances during the use of the 

product. The warranty is limited to the repair or exchange of the product by the authority of the 

company or the agency, for problems in materials or the manufacturing process which occurred 

during use under normal circumstances.

The company has no legal responsibility for the confirmation of services, declarations or whole 

warranty beyond the warranty specified above, which were supplied or will be supplied by the 

agency or the staff of the company at their own discretion. The user cannot request the company of 

services, declarations or whole warranty which were supplied or will be supplied by the agency or 

the staff of the company at their own discretion based on the statements above. 

The contents of this warranty represent all other warranties indicated or implied, and also represent 

all kinds of service- related responsibilities of the product sellers for the product they sell.

The product was manufactured under strict quality controls and  the inspection process of the 

company. The indemnification standard for product repair and exchange is according to the 

Economic Planning Board notification 

Regulation for the indemnification of consumer damage

Some symbols are used in this manual to help users or patients use this product safely and 

appropriately and to prevent any risk to patients or damage to materials. Please read and understand all 

warnings and precautions.

Each symbols mean : 

Product Guarantee

PalmCare plus

Contacts

Symbols in the Manual

The “Warning” symbol indicates that a dangerous situation may occur 

resulting in fatal injury or death of the patient, or may incur material and 

financial damage when the warning is ignored.

The “Caution” symbol indicates that a situation may occur resulting in injury 

or damage to the patient, though not life-threatening, when the caution is 

ignored.

The “Note” symbol is used to inform you of important, but not dangerous, 

information regarding installation, use, and maintenance of the product.

WARNING

CAUTION

NOTE

Summary of Contents for PalmCare plus

Page 1: ...ang gu Seongnam si Gyeonggido 13486 Korea Dir 82 31 696 4899 Fax 82 31 696 4877 Customer Service Dept Dir 82 31 696 4899 Fax 82 31 696 4877 European Representative Medical Econet Gmbh Quality Assuranc...

Page 2: ...OPERATION MANUAL PalmCare plus Handheld Pulse Oximeter Ver 1 3 NOV 10 2017...

Page 3: ...4 Bottom Side 2 5 Back Side 3 Description of Product Symbols 3 1 Screen configuration 4 Palmcare plus Basic Operation 4 1 Operation 3 3 3 4 5 8 9 9 10 10 10 10 11 12 12 12 12 12 12 13 13 16 16 5 Envi...

Page 4: ...special circumstances during the use of the product The warranty is limited to the repair or exchange of the product by the authority of the company or the agency for problems in materials or the manu...

Page 5: ...determining necessity of treatment for the patient WARNING Locations where moisture level increase considerably or where air is not ventilated properly Locations where sudden impact or vibration could...

Page 6: ...battery from the product To ensure the lifecycle and safety of battery please discharge the battery and then charge perfectly again every six months Also time worn battery exceed 24 months should be...

Page 7: ...ttings Pay attention when setting Palmcare plus for the following points Use Palmcare plus under conditions of 10 40 of circumstantial temperature and 30 85 humidity Check the connection status of the...

Page 8: ...ction parts power line or any optional device are connected to the device properly Noise may be made if the device isn t completely grounded Precautions for using Do not disassemble the device Do not...

Page 9: ...for how to set up each initial display mode In order to avoid electrical shock do not open the cover Disassembling of the equipment must be done only an by service personnel who is authorized by BION...

Page 10: ...ds Function of the buttons Each buttons on the PalmCare plus services more than two use according to the screen The use meaning for each screen is as below chart Button Display mode Meaning and Operat...

Page 11: ...56 to 299 On the contrary if high limit value for HR is 150 the LOW value range for HR can be adjusted as some numbers between1 to 149 The value range for SpO2 also can be applied of the same rule of...

Page 12: ...arm ringing when a probe has slipped off or when a probe connector is pulled off from the Palmcare plus At this time this is an item to decide wether this information alarm will activate setting on or...

Page 13: ...end Time Setting 5 3 Initial Display Setting Mode Display Mode Step1 You can enter to the initial display setting mode if you press ENTER button after making a reverse the item 2 DISPLAY MODE on the e...

Page 14: ...Sound Off Volume Off ii 2 Sound Low Low volume iii 3 Sound High High volume Step3 You can return automatically to the SETUP screen if you choose the mode by ENTER button And if you want to cancel the...

Page 15: ...e ENTER button after making a reverse the item 7 Device Info Step2 You can use UP DOWN button for the item moving and ENTER button for your choice Brightness LCD Brightness auto control setting i ON I...

Page 16: ...00 00 for initial trend saving time Saved SpO2 value Save HR Value Event data which is saved by the user Data mark which is saved by Medium PriorityAlarm Data mark which is saved by High PriorityAlarm...

Page 17: ...atal patients make sure the disposable probe should be used outside the incubator The humid atmosphere inside the incubator can cause inaccurate measurements Alarms for Each Mode Standard Mode The hig...

Page 18: ...ower has to be supplied at once For the effective use of battery Palmcare plus has the power saving mode it turn off the LCD back light after 3 seconds and also turn off the all functions of Palmcare...

Page 19: ...act our Customer Service Dept orA S receptions 10 Before Requesting After Service Problem Solution 1 In case of the battery is discharged Connect DC adapter 2 Please check the connection of the switch...

Page 20: ...ation and Pulse rate Memories 72 hours maximum Physical Dimension 165mm H X 70mm W X 30mm D 1CELL 200 g 2CELL 250 g StandardAccessories Finger Probe 5V 2 0ADCAdapter OptionalAccessories USB mini B Typ...

Page 21: ...omer s Damage Compensation Regulation noticed by Economic Planning Board This product is medical equipment Product Warranty Product Name Model Code Manufacture Approval No Manufacture Approval Date Ma...