background image

BIONIZER  

POOL MANAGEMENT SYSTEM

Dear Bionizer Owner,

Congratulations and thank you for choosing the Bionizer 
Pool Management System.

By purchasing this product you have taken a major step 
towards helping the environment, as well as the health of 
your family.

Superior Pool System

We have developed one of the most superior pool and spa 
management systems on the market today.

The  Bionizer  pool  ionizer  manages  your  pool  superbly 
while  you  spend  your  valuable  time  relaxing  in  your 
environmentally sensible and healthy pool.

No more dry skin and hair. No more red eyes. No more 
corrosive salt. Now you and your family will be swimming 
in  pure  sanitized  mineral  water  that  needs  only  small 
amounts of oxidizer to remain crystal clear and healthy.

The  important  point  is  that  with  Bionizer 

this  occurs 

without an overload of hazardous, costly chemicals or 
corrosive salt !

Olympic Swimmers Use Ionization 
Currently the most common way of sanitizing your pool is 
by  using  environmentally  degrading  and  costly  pool 
chemicals. This also applies to controlling algae in your 
pool.

Yet, ionization is a well tried and long time proven natural 
alternative to chemical-based pool treatments. Ionization 
is  endorsed  &  embraced  by  the  World  Health 
Organization  (WHO)  and  the  US  EPA  -Environmental 
Protection Authority.

Ionization does not ever exacerbate asthma or eczema as 
high levels of chlorine are shown to do. Many USA Public 
Pools  have  chosen  ionization  as  their  primary  form  of 
sanitation and pool control and the public who use these 
pools have overwhelmingly endorsed this choice.

Our Bionizer is used on many Eco-Award swimming pools, 
learn to swim pools, health resort pools and public pools 
in over 18 countries

NASA Developed Ionizers 

Ionizers  have  been  used  for  sanitizing  water  for  many 
years now and were refined by NASA in the 1960's for its 
space program.

The main function of ionizers is to control the growth of 
micro-organisms in bodies of water.

They  are  in  widespread  use  in  water  towers  for  air 
conditioning  systems  where  they  efficiently  control 
Legionella  bacteria  that  cause  the  deadly  Legionnaires' 
disease,  whilst  reducing  the  chemicals  that  promote 
structural decay.

In Australia the  APVMA, the government authority in 
regards  to  pool  &  spa  chemicals  (APVMA  -  The 
Australian  Pesticides  &  Vetinary  Medicines  Authority) 
requires  that  a  registered  sanitizer  be  used  with  this 
product when the pool is used for bathing. Bionizer uses 
only official APVMA Authorized Anodes.

The Bionizer Eco-Oxidizer creates Hydroxyl Radicals and 
Peroxy Compounds electrochemically and these products 
effectively  impart  a  powerful  oxidative  effect  into  your 
pool  water  when  the  pump/filter  is  running.  If  using  a 
Bionizer  and  Eco-Oxidizer  we  advise  that  the  pump  is 
running when bathing.

Happy Swimming!

4

INSTRUCTION BOOK

Summary of Contents for 60564

Page 1: ...INSTRUCTION BOOK BIO EFFECTIVE POOL AND SPA PURIFIER Read before you call us for advice APVMA Product No 60564 Label Approval No 60564 01 0106 Version 2 28c 26 Sep 2017...

Page 2: ...oolpumpintotheBionizerandplugBionizerControlunitintopower o Enterrealtimeofdayasperpage13 o Enterpoolsize volume asperpage13 o Enterdesiredpumpingtimes 4pumpingsessionsavailable asperpage14 o Ensureth...

Page 3: ...eneficial ions Bionizer Pty Ltd has harnessed the three of these technologies to protect and maintain your pool water in the most powerful natural way known on Earth The Eco Pool Partners Nothingismor...

Page 4: ...s not ever exacerbate asthma or eczema as high levels of chlorine are shown to do Many USA Public Pools have chosen ionization as their primary form of sanitation and pool control and the public who u...

Page 5: ...OR CABLES CONNECTION FOR POOL PUMP AND OTHER MAINS POWERED DEVICES pH BOSS OR ECO OXIDIZER CAN BE POWERED FROM HERE MAXIMUM COMBINED OUTPUT FOR BOTH POWER OUTLETS IS 9 5 AMPS 2280 WATTS CONNECTING MOR...

Page 6: ...ns Scan this QR Codewithyour smartphone or tablet to download a PDF copy of the Bionizer manual from the Bionizer Web Site CAUTION Your warranty could become invalid should you fail to observethefollo...

Page 7: ...nAutomaticTimermode andthePoolPumpisswitchedoff page15 NOTE When the Bionizer is displaying it is not indicating the Bionizer unit is switched Auto Off in any way It is merely indicating that the Pool...

Page 8: ...s FOR BOTH EXISTING AND NEW POOLS Test your pool water for pH Total Alkalinity Calcium Hardness Phosphates and balance the pool to the followinglevels pH 7 0 7 4pH TotalAlkalinity 80 120ppM 150 180 pp...

Page 9: ...a pH BOSS now you may want to leave a space for the pH BOSS Tee Piece Fitting This requires 20cm of HORIZONTAL pipe BEFORE theOxiPod BIOPOD CARTRIDGE INSTALLATION 9 Scan this QR Code with your smartph...

Page 10: ...whichanode 5 Plug the pump power cable into either of the outlet socketsatthebaseofthecontrolbox The spare mains power outlet can be used for any mains powered device that will operate whenever the po...

Page 11: ...ol water This may save youanalgaeattack Salt Bionizer ssmartsoftwareallowsforlargevariationsinsalt level without compromising performance so there is no need to empty and refill water in your pool if...

Page 12: ...r installations where a multi speed pump is being used increasethespeedtoahighersettingtoensurea higherflowratethroughtheBioPodAnodecartridge Alternatively add additional Start up Ions to the pool wat...

Page 13: ...f you selected Enter Calculator the following screen will now be displayed Use the buttons to set the Pool Length in metres Press to save the setting and go to PROGRAM SET setting the Pool Width Use t...

Page 14: ...30 minute increments Press oncetogoontosettingthetime PROGRAM SET whensessionAwillfinish Use the buttons to set the OFF A time in 30 minute increments Setthe ON and OFF timesfortheremainingpumptimer...

Page 15: ...unsafe forswimming Boost Unit operates the Pool Pump and Ionizing outputs for a calculated number of hours to boost Copper level The number of boost hours is calculated from the Pool Size setting and...

Page 16: ...ce in pool ionizing we have made the initial ionizing settings extremelyeasyforthefirsttimeuser WhenyouenteredyourPoolSizeduringthefirsttime start up the Bionizer automatically adjusted the Ionizing O...

Page 17: ...Total Alkalinity which requirelookingthroughthesideofthetesttube To use the copper ion test look down through the top ofthetubewiththecapoff Depending on the kit supplied the colour comparison chart i...

Page 18: ...hart Of particular importance is pH which MUST be between 7 0 to 7 4 in order for the Copper Iontesttoshowacorrectreading Make a note of the Copper reading which you will needtoenterintotheBionizerwhe...

Page 19: ...thysparklingbodyofwater 3 TESTS EACH WEEK Testeveryweek adjustifrequired 1 pH 7 0 7 4pH 2 Copper 0 5 0 6ppM 3 TotalAlkalinity 80to120ppM 2 TESTS EACH MONTH If weather conditions are very wet windy the...

Page 20: ...no water passing the anodes when the Bionizer is operating no damage to the unit or pool equipment will result and there will be no risk of fire or explosion as can occur with many salt chlorinator e...

Page 21: ...quite small the Bionizer may not be able to pass enough current between them to maintain the correct Copper level At this time the MAX OUTPUT LED startstoflash Reducing the Ionising Output page 14 ca...

Page 22: ...patible with Bionizer This specially formulated flocculant does not remove metals from the water and traps the residue in the filter where it is easily backwashed away This saves havingtovacuumthepart...

Page 23: ...e rapidly as unstabilized Chlorine is 90 removed from your pool in 3 hours of sunlight leaving the pool ready to swim in once again Refer super chlorinationsection 18 DO NOT use any form of stabilised...

Page 24: ...ionize mode use the copper testkittocheckthewaterinthebucket Itshouldshow copperionsarenowpresentinthewater 6 If there are no ions present in the water repeat the same test but using fresh tap water...

Page 25: ...you continually mistake this for algae and continue the chlorine cycle until the pollen season is finished you will suffer the effects of too much chlorine and your pool will be out ofcontrol 8 To rec...

Page 26: ...filtermedium We don t recommend D E filters as the medium can double the number of anodes required for efficient operation And who needs the expense and hassle of an oldschool D E filteranyway For Car...

Page 27: ...in copper but the bucket test showsahighresult followthisprocedure a Backwash the filter for 15 seconds or so and then stop b Then backwash the filter again for a second or two and capturea smallamoun...

Page 28: ...ease your acid usage The water may tinge clear green if the T A gets too low for any period of time The ionizer will not cause any corrosion if the T A is low under 60 The levels of water balance that...

Page 29: ...em areas that you need to check for further algae infestation Ifyouhaveapoolblanket washdowntheundersideof the blanket with liquid chlorine as there will be algae spores attached there An easy and saf...

Page 30: ...ier to help remove any dead algae from the pool water This prevents the dead algae from creating a level of phosphates again whichmaycauseasecondalgaeattack Don t use any flocculants that remove metal...

Page 31: ...leveliscorrect add one bag of salt per 50 000L pool size to increase the conductivity of the pool water Message No RTC Example Meaning The real time clock function of the Bionizerisfaulty Solution Swi...

Page 32: ...ip If the house breaker trips this positively indicates afaultypoolpump Even if the pool pump does not trip the house breaker it could still be faulty for example a failed capacitor This is because th...

Page 33: ...Chlorinated and Chlorinepools ThepH BOSS issuppliedready to useoutofthebox Scan the QR Code to link directly to the pH BOSS website orgotowww phboss com TM COMBINING NATURAL OXYGEN AND ELECTRO CHEMIST...

Page 34: ...tosparklingclarity CompatiblewithallIonized SaltChlorinatedandChlorinePools Doesnotaffectoverallpoolbalance Highlyconcentrated canbeusedwithoutpre mixing Pool Water Clarifier Blue Super concentrated P...

Page 35: ...otal Dissolved Solids TDS Period Weekly Weekly Weekly Monthly Monthly Quarterly Treatment Product Hydrochloric Acid 50mL 10 000L pH 0 1 Bionizer Program Settings Turn output Up or Dn Buffer Soda Bi Ca...

Page 36: ...T SAVE TIME MONEY SAVE YOUR LONG TERM HEALTH Bionizer Pty Ltd 1 173 Bradman Ave Maroochydore QLD 4558 Australia Postal address PO BOX 473 Maroochydore QLD 4558 Australia Phone 61 7 5479 6100 Fax 61 7...

Reviews: