FITTING 50mm BIOPOD CARTRIDGE
(2-60L, 2-120L, 2-250L, 2-500L)
1. 50mm Pipe : Cut out a 175mm section of pipe sufficient for
the BioPod and 50mm barrel unions.
40mm Pipe : Cut out a 165mm section of pipe sufficient for
the BioPod and 40mm barrel unions.
2. Slide the barrel union nuts onto the pipe. Ensure that the
threads are facing the correct way, so that the nuts can be
screwed onto the BioPod at the last stage of installation.
3. Glue the barrel union halves onto the pipe. Use either the
50mm or 40mm barrel union halves, depending on your
return pipe size. Do not lose the O-rings from the unions,
and ensure that they are in place before fitting the BioPod
in place.
4. Fit the BioPod into place and secure the barrel union nuts.
Hand tighten only - do not use a tool.
Fit the ring connectors onto the bolts on each side of the
BioPod and tighten the wing nuts securely. The rings can
b e f i tt e d t o e i t h e r a n o d e b o l t s . T h e re i s n o
+ / - polarity for the connections.
FITTING 40mm BIOPOD CARTRIDGE
(2-30L)
1. 40mm Pipe only: Cut out a 110 mm section of pipe
sufficient for the BioPod and 40mm barrel unions.
For 50mm pipe, contact Bionizer to upgrade to a 50mm
BioPod.
2. Slide the barrel union nuts onto the pipe. Ensure that the
threads are facing the correct way, so that the nuts can be
screwed onto the BioPod at the last stage of installation.
3. Glue the barrel union halves onto the pipe. Do not lose the
O-rings from the unions, and ensure that they are in place
before fitting the BioPod in place.
4. Fit the BioPod into place and secure the barrel union nuts.
Hand tighten only - do not use a tool.
Fit the ring connectors onto the bolts on each side of the
BioPod and tighten the wing nuts securely. The rings can
b e f i tt e d t o e i t h e r a n o d e b o l t s . T h e re i s n o
+ / - polarity for the connections.
PLANNING THE BIOPOD CARTRIDGE
INSTALLATION
!
Locate a section of pipe where the BioPod can
easily fit.
!
Ensure that there is a minimum of 10cm of straight
pipe AFTER the BioPod.
!
The BioPod cartridge can be fitted horizontally or
vertically, so it can be mounted where it is
convenient and easy to install.
!
If you are installing a pH BOSS and/or Eco-Oxidizer,
the fittings MUST be installed in this order :
1. pH BOSS Probe and Injection Tee
2. Eco-Oxidizer OxiPod Oxidizing Cartridge
3. Bionizer BioPod Ionizing Cartridge
The OxiPod and BioPod cartridges can be fitted
horizontally or vertically, as long as they are in the
order shown above.
!
HINT :
Even if you are not installing a pH BOSS now,
you may want to leave a space for the pH BOSS Tee-
Piece Fitting. This requires 20cm of HORIZONTAL
pipe BEFORE the OxiPod.
BIOPOD CARTRIDGE INSTALLATION
9
Scan this QR Code with your smartphone
or tablet to go to the BioPod installation
video on the Bionizer web site.
10cm
(minimum)
Filter
Pressure
Pool
Pump
10cm
10cm
NOTE THAT THE 10cm SPACINGS SHOWN ABOVE ARE
FROM THE EDGES OF THE PODS, NOT THE CENTRE
OF THE PODS.
Oxidizing Pod
Ionizing Pod
Filter
For sand filters,
glass or silica sand
media provides
optimum results.
FLOW DIRECTION
40mm Pipe: 110mm
Cut pool return pipe
FITTING 40mm BIOPOD CARTRIDGE
(2-30L)
1. 40mm Pipe only: Cut out a 110 mm section of pipe
sufficient for the BioPod and 40mm barrel unions.
For 50mm pipe, contact Bionizer to upgrade to a 50mm
BioPod.
2. Slide the barrel union nuts onto the pipe. Ensure that the
threads are facing the correct way, so that the nuts can be
screwed onto the BioPod at the last stage of installation.
3. Glue the barrel union halves onto the pipe. Do not lose the
O-rings from the unions, and ensure that they are in place
before fitting the BioPod in place.
4. Fit the BioPod into place and secure the barrel union nuts.
Hand tighten only - do not use a tool.
Fit the ring connectors onto the bolts on each side of the
BioPod and tighten the wing nuts securely. The rings can
b e f i tt e d t o e i t h e r a n o d e b o l t s . T h e re i s n o
+ / - polarity for the connections.
Glue 40mm barrel
union halves onto
pipe.
Slide barrel union nuts
onto the pipe, facing
the correct way.
40mm Pipe: 165mm
50mm Pipe: 175mm
Cut pool return pipe
FITTING 50mm BIOPOD CARTRIDGE
(2-60L, 2-120L, 2-250L, 2-500L)
1. 50mm Pipe : Cut out a 175mm section of pipe sufficient for
the BioPod and 50mm barrel unions.
40mm Pipe : Cut out a 165mm section of pipe sufficient for
the BioPod and 40mm barrel unions.
2. Slide the barrel union nuts onto the pipe. Ensure that the
threads are facing the correct way, so that the nuts can be
screwed onto the BioPod at the last stage of installation.
3. Glue the barrel union halves onto the pipe. Use either the
50mm or 40mm barrel union halves, depending on your
return pipe size. Do not lose the O-rings from the unions,
and ensure that they are in place before fitting the BioPod
in place.
4. Fit the BioPod into place and secure the barrel union nuts.
Hand tighten only - do not use a tool.
Fit the ring connectors onto the bolts on each side of the
BioPod and tighten the wing nuts securely. The rings can
b e f i tt e d t o e i t h e r a n o d e b o l t s . T h e re i s n o
+ / - polarity for the connections.
Glue 50mm or
40mm barrel union
halves onto pipe.
Slide barrel union nuts
onto the pipe, facing
the correct way.