10
[Drawing 1]
[Drawing 2]
Place of hole drilled
6. Connect the standard connection hose (1/4”) to the adapter
installed with one touch fitting of union. (Drawing 3~4)
Insert the inlet hose into the one touch fitting and insert
the safety pin as in drawing.
( Pls check if the hose has been securely fitted to the end of one
thouch fitting. if not, it causes water leakage for water pressure )
7. After the connection, adjust the water pressure control
screw of the adaptor to an appropriate level.
(Alkaline water flow standard : 1.5±0.5ℓ/min )
8. Check any possible water leakage at the connection parts
after the installation
Groover
Cold water
1. Prepare the tools for installation as drawing : Electric drill,
Hole cutter, Pipe wrench or spanner, General screwdriver,
Teflon tape 1pc (Drawing 1.)
2. Turn off the water valves before installation under the
sinkdeck.
3. Disconnet the water tap from the cold water pipe.
4. Drill a hole for the 1/4” hose appropriate place
somewhere in sinkdeck and make the connection to the
inlet of the product
5. Find the cold water pipe inside the sink deck and connect
the adapter to the cold water pipe (Drawing 2.)
■Should use the standard inlet hose (1/4”) and fix the
valve cover in the direction of the hose to prevent the
hose from being bent or fastening nut from being loosened.
[Drawing 4]
■ The following tools ate necessary for installation work
Pipe wrench
or spanner
General
screwdriver
Teflon tape
Electric drill
Hole cutter
Size:
Diameter1/4”
2. Deck type sink mounted water tap
Hot water
Water valve of Cold water
Ring nut
Water pipe
Steel Hose
[Optional]
Acidic Water Outlet
Water pressure control
screw (Spindle)
Running water line
connection Adaptor(small)
[Drawing 3]
BTM-303D (영).indd 10
2016-08-31 오후 1:26:09