The pH values (Ion concentration) of the generated alkaline or acidic ionized water can be measured.
■ Check the generated water after adjusting the water pressure to meet the standard water flow volume (1.5
l
+ 0.5
l
/Min.)
according to the ionized water generation method.
(The pH values can vary depending on the quality of water and the flow volume)
■ Materials to be prepared: The pH Reagent - parts
■ How to measure
1. Let the generated water (Alkaline or Acidic ionized water) flow through for about 10 seconds.
2. After filling a transparent glass with 1/3 of the water, put 2~3 drops of the pH reagent into the water and shake it.
3. Compare it with the pH colorimetry.
Please take note
■ The color of the test solution will change as time goes by. (Compare the color of the test solution with the pH colorimetry
before too much time passes by after dropping the test solution into the water)
■ When disposing of the undiluted test solution, you need mix it with water to make it light before letting it flow out.
■ When the pH concentration is measured, the color of the test solution can come out differently compared with the pH
colorimetry due to the effect of various substances dissolved in the water such as carbonic acid gas.
■ The pH color of the alkaline or acidic ionized varies depending on the pH level.
19
Caution
Caution
● Do not let the pH regent contact the eyes and do not drink it.
- In case of drinking it by mistake, you need to drink lots of water. In case of the test solution contacting
the eyes, you need to clean your eyes with sufficient water and then consult a doctor.
● Do not place it near any heat of fire. If not followed, fire can be caused.
● Do not store the regent in a place where it can be reached easily be children. Avoid any place where
the temperature or moisture level is high
pH (ion concentration) Measurement
Indication light for water draining
Filter Replacement Period
Indication for filter replacement
The pH test solution is an expendable item. It can be purchased at the sales shop or the main office.
Indication of operation
in progress
Indication of operation in progress
1. Open the water supply control valve to let the water flow in to generate
the alkaline ionized water of the set value.
2. Push the purified water indicating button.
- Indication light for purified water selection
Voice guidanc "Crystal clear water on precess"
3. Use the purified water.
4.When the water supply control valve is turned off in the middle of
the water being used, the selection of the purified water is called
off and the setting will return to the previously set value of Alkaline .
In order to stop the operation in the middle of the use, other
selection buttons need to be pushed to select other functions.
■ When the indication light for the purified water is turned off.
When there is a change in the water pressure leading to the lowering
of the water level, the indication light will be turned off and the setting
will be returns to the previously set value of ‘Alkaline’. Use the
product by setting the value again after adjusting the water pressure.
When the water supply is opened after the rinsing is finished, the indication light
for water draining will blink automatically together with a voice guidance. After
about 0.2ℓ of water is drained the indication light will be turned off, and the
setting will return to the previously set value of ‘Alkaline’ for the
operation. (Do not drink the drained water )
Voice guidance :“ Drain out, wait for a moment please.”And when the draining is
finished, there will be a voice guidance will say“ Alkaline Ionized Water on process.”
■ In the following cases, the replacement period can be shortened drastically:
● When there is rusty water due to aged pipes
● Lots of impurities in the water for a short period of time
● If the product is used in a place where the water pressure is low.
■ When the water tastes changes or the water flow volume decreases dramatically,
you need to check whether the life span is overdue.
■ When the filter usage status indicating number becomes "999" , it will blink.
It is recommended to replace the filter even before the end of life span is
reached, if the water smells or the water flow volume decreases, considering the
life span can be different depending on the quality of water in individual areas
Service Call : 82-1644-3853
When the water supply control valve is
opened after the rinsing, about 0.2ℓ of
water will be drained.
Filter Replacement