A. INSTALLATION GUIDE 4. INSTALLATION OF THE TANKS
PAGE
11 / 51
Installation and User guide – ECOROCK - Systems – 26-05-2016
4.
INSTALLATION OF THE TANKS
This chapter provides a guide to the installation and commissioning of the BIOROCK® system. This
manual cannot be a substitute for documentation and instructions from manufacturers of non-
BIOROCK® products integrated into the system by the user.
Please take photographs of each stage of the installation with particular
attention to all of the connecting pipework
DO NOT completely fill the tanks with water before unit is backfilled
DO NOT use dirty or contaminated water
DO NOT use a mechanical compactor, only compact manually
DO NOT reuse the excavated soil or spoil from the site
DO NOT install the system too close to the house or other buildings
DO NOT install the system too close to large trees
4.1 INSTALLATION PRINCIPLE
Dimensions and weight of the ECOROCK treatment units:
ECOROCK-1500
Value
Measure
Capacity in Person Equivalent (PE)
*1
6
PE
Volume of the ECOROCK-5000 unit
1.500
Litres
Length of the Tank
1.150
mm
Width of the Tank
1.150
mm
Height of the Tank
2.175
mm
Height difference water inlet – water outlet
1.098
mm
Total weight (empty) of the ECOROCK-5000 unit
186
Kg
Pipe diameters
110
mm
Cover (round)
Ø 700
mm