B. USER GUIDE 3. RECOMMENDATIONS FOR OPERATION AND MAINTENANCE
PAGE
32 / 47
Installation and User guide – ECOROCK 700 to 900 Units – 05-12-2016
3.
OPERATING & MAINTENANCE RECOMMENDATIONS
An annual service and maintenance contract should be set up for your BIOROCK system. Contact
your dealer if necessary or contact us for more details about the closest dealer to you.
BIOROCK highly recommends users to set up a maintenance contract with their local dealer or
Certified Installer to ensure the long lasting efficiency of BIOROCK products. Completing the
maintenance book together with a BIOROCK Certified Professional is a condition for warranty.
However, should you be unable to get this service locally, BIOROCK can provide a maintenance
planning schedule giving an overview of the maintenance procedures. This planning schedule will
allow a professional in the wastewater industry to provide the maintenance service.
Please check with local authorities how often the primary compartment should be emptied as this
should be in line with local regulations.
The summary below indicates the commissioning of your sewage treatment plant. Your sewage
treatment plant can be free from any failures as the BIOROCK system does not require electricity. (In
normal operation, and following the maintenance recommendations)
GENERALLY:
Every year:
Visually check the water tightness of the complete system
Check the ventilation
Check if there are any smells exiting the tanks
PRIMARY TANK
Every year:
Check the sludge level
Empty the Primary Tank if the sludge level is > 50%
Change the effluent filter if necessary or change after emptying the Primary Tank
Take a sample of the effluent form the Primary Tank and check quality visually
ECOROCK UNIT
Every year:
Clean the water distribution system
Check the top layer of the BIOROCK media, clean if necessary (Cf. Procedure B/Ch 3.2)
Check and clean the alarm if necessary
Take a sample of the outgoing water (final effluent) and check for clearness and odour.
Clearness means that the water contains few suspended particles. The colour may vary
from neutral to dark yellow. The odour of the water will normally be neutral to light
ammonia.
Neutral
Dark yellow