background image

cuff begins to inflate while the increasing cuff pressure is displayed on the screen. After the suitable 

inflation pressure is reached, the cuff stops inflating and the pressure gradually falls. A long beep 

sounds when the measurement is completed. The systolic and diastolic blood pressure values along 

with the pulse rate are displayed on the screen. The measurement is displayed for approximately 1 

minute.

2.  Switch off the device by pressing the   button to preserve the batteries. If no button is pressed for 1 

minute, the instrument switches the display off.

NOTE:

 The time will continuously be displayed on the screen.

3.5 Appearance of the Atrial Fibrillation Indicator (only in MAM mode)

This symbol 

 indicates that atrial fibrillation was detected during the measurement. If AFIB is 

present during blood pressure measurement, the AFIB Indicator is displayed. The AFIB 

 will flash 

8 times rapidly once the measurement is complete and then stop flashing. In this case, the result may 

deviate from your normal blood pressure. It is highly recommended to take an additional measurement 

an hour later to increase the specificity of the detection. In most cases, this is no cause for concern. 

However, if the symbol appears on a regular basis (e.g. several times a week with measurements taken 

daily) we advise you to visit your doctor. Please, provide the following explanation:

Information for the doctor on frequent appearance of the atrial fibrillation indicator

This instrument is an oscillometric blood pressure monitor that also analyses pulse frequency during 

measurement. The instrument is clinically tested.
The 

 symbol is displayed after the measurement, if atrial fibrillation occurs during measurement. If 

the symbol appears more frequently (e.g. several times per week on measurements performed daily) we 

recommend the patient to seek medical advice. The instrument does not replace a cardiac examination, 

but serves to detect atrial fibrillation at an early stage.
•  Sometimes the device will detect atrial fibrillation even when it is not there. This can happen if the 

arm moves during the reading or another rhythm problem is present. Keep the arm still during the 

reading. Visiting your doctor with this device may be necessary to check out any rhythm problems.

•  This device may not detect atrial fibrillation in people with pacemakers or defibrillators.

Summary of Contents for ULTRA 3MS1-4Y

Page 1: ...Blood Pressure Monitor ULTRA With Atrial Fibrillation Screening Instruction Manual Model 3MS1 4Y www biosmedical com Go to biosmedical com for a FREE Log Book 06 05 21 ...

Page 2: ... that millions of our home use monitors have been used by Canadians in the last 30 years All BIOS Diagnostics devices are developed in collaboration with physicians and clinically tested to prove their measurement accuracy For more information on clinical tests and other BIOS medical products visit our website at www biosmedical com If you have questions about this device or blood pressure monitor...

Page 3: ... Facts about Atrial Fibrillation AFIB 1 7A What is Atrial Fibrillation 1 7B How Does AFIB Impact my Family or Me 1 7C AFIB Detection Provides a Convenient Way to Screen for AFIB only in MAM mode 1 7D Risk Factors You Can Control 2 Getting Started 2 1 About the 3MS1 4Y 2 2 About the LCD Screen 2 3 Inserting the Batteries 2 4 Using the AC Adapter 3 Using the Device 3 1 Setting the Time and Date 3 2 ...

Page 4: ... 8 Clearing All Values 3 9 Discontinuing a Measurement 3 10 Determining Your Real Average Blood Pressure at Home 4 Software Functions 5 Error Messages Malfunctions 6 Care and Maintenance 7 Lifetime Limited Warranty 8 Technical Specifications ...

Page 5: ...ogy for the early detection of atrial fibrillation AFIB and hypertension These are the two top risk factors of heart disease and stroke which increase the risk of getting a stroke or heart disease in the future It is important to detect AFIB and hypertension at an early stage even though you may not experience any symptoms Appropriate treatment can reduce your risk of suffering a stroke For this r...

Page 6: ...mmend that you record your blood pressure regularly at home as well as at your doctor s clinic Try to record your blood pressure regularly at the same time of the day and under the same conditions This will help your physician detect any extreme variations in your blood pressure and thus treat you accordingly Morning Hypertension 135 85 mmHg Recently several studies have identified elevated cardio...

Page 7: ...ight high humidity or in places with a lot of dust Clean the device with a soft dry cloth Do not use gasoline thinner or similar solvents Carefully remove spots on the cuff with a damp cloth and soap Do not wash the cuff Do not use the device if you think it is damaged or if anything appears unusual Ensure that children do not use this device unsupervised some parts are small enough to be swallowe...

Page 8: ...ve been damaged If the unit turns on and does not display an error code the product is working properly In extremely rare cases the cuff may have developed a pin hole leak or the gasket where the cuff connector enters the monitor may not have a proper seal both of these leaking air issues will potentially cause errors in accuracy but otherwise the product will work accurately without drifting out ...

Page 9: ...cuss with your medical professional medication s and lifestyle modifications are necessary to control your hypertension Adapted From Understanding and Managing your blood pressure Hypertension Canada Note A diagnosis of high blood pressure must be confirmed with a medical professional A doctor should evaluate any unusual blood pressure readings Additionally lower targets may be appropriate for som...

Page 10: ...enting potential health problems Expert opinion suggests patients with normal blood pressure can benefit from one week of measuring every three months 1 6 About MAM Technology Average Mode technology is a new technology that enables optimum reliability in self measurement of blood pressure An advanced measurement accuracy is achieved by the automatic analysis of three successive measurements with ...

Page 11: ...art beat You can live with atrial fibrillation but it can lead to other rhythm problems chronic fatigue heart failure and worst of all a stroke You will need a doctor to help you control the problem 1 7B How Does AFIB Impact Family or Me One in every six strokes is AFIB related While individuals above the age of 65 are more likely to have AFIB individuals as young as 40 can exhibit AFIB Early diag...

Page 12: ...mory Button Adapter Socket USB Port MAM Switch Cuff Connection Cuff Connector Battery Compartment Wide Range Cuff Time Button b Upper arm cuff Type BD086 wide range cuff is for arm circumference 22 42 cm or 8 75 16 5 Cuff connection Insert the cuff tube into the opening provided on the left side of the monitor as shown in the diagram ...

Page 13: ...k Indicator Arm Movement Indicator 2 3 Inserting the Batteries Follow these steps to insert the four AA batteries in the device 1 Open the battery compartment cover in the direction shown 2 Insert the four AA batteries with the correct polarity as indicated 3 Replace the battery compartment cover Attention After the battery warning appears the device is blocked until the batteries have been replac...

Page 14: ...the button down to test all the display elements When functioning correctly all segments must appear 3 Using the Device This section describes how to get the maximum benefit from your 3MS1 4Y blood pressure monitor Follow the instructions carefully to get an accurate measurement of your blood pressure and pulse rate 3 1 Setting the Time and Date When you insert the batteries for the first time see...

Page 15: ...ed and error code displayed Note AFIB detection can only be done in MAM mode Single Mode a If you would like to take a single mode measurement please move the slide switch to the left b Single mode only has 1 measurement 3 3 Obtaining Accurate Measurements Your blood pressure can vary based on numerous factors physiological conditions and your surroundings Follow these guidelines to obtain accurat...

Page 16: ...m for a video that illustrates how to properly fit the cuff a Putting the cuff velcro side down on a table the words on the cuff should be facing right side up Put the end of the cuff with fastener through the metal ring making the cuff a cylinder Ignore this step if your cuff is already set up Proper assembly allows the Velcro to match up properly Measure on your non dominant arm unless there is ...

Page 17: ...tes before repeating measurement j If this device was stored in low temperature it is necessary to leave it in room temperature for at least 1 hour otherwise the measurement can be inaccurate Comment Continue to use the same arm for comparisons It is not unusual for there to be a difference in blood pressure between arms Initially check BP on both arms If one arm is 10mmHg higher continue to measu...

Page 18: ...urement an hour later to increase the specificity of the detection In most cases this is no cause for concern However if the symbol appears on a regular basis e g several times a week with measurements taken daily we advise you to visit your doctor Please provide the following explanation Information for the doctor on frequent appearance of the atrial fibrillation indicator This instrument is an o...

Page 19: ...ertension zone If the arrow points to the sixth bar it is in the red Stage 3 Hypertension zone 3 7 Viewing Previously Recorded Values The blood pressure monitor automatically stores your measurements It can store up to 200 measurements When more than 200 measurements are made the oldest readings are deleted to make space for the new ones To view the previously stored values press the button The la...

Page 20: ...orning before breakfast before taking medication Sit with back supported and measurement arm resting on a table Sit with feet flat on the floor PM Take 2 measurements 1 minute apart Empty bladder If necessary 2 hours after dinner before taking medication Sit with back supported and measurement arm resting on a table Sit with feet flat on the floor Avoid coffee and smoking within the hour and no ex...

Page 21: ...ill then flash to indicate that the connection between computer and device is successfully made As long as the cable is plugged in the bars will keep flashing and the buttons are disabled During the connection the device is completely controlled by the computer Please refer to the help file in the software for detailed instructions 5 Error Messages Malfunctions If an error occurs during a measurem...

Page 22: ...ew ones The pressure does not rise even though the pump is running Check the connection of the cuff tube and connect properly if necessary The device frequently fails to measure the blood pressure values or the values measured are too low or too high 1 Check the positioning of the cuff 2 Measure the blood pressure again ensuring that you have remained motionless for a sufficient amount of time to ...

Page 23: ...ects for the life of the original owner This warranty does not include the inflation system including the cuff and inflation bladder The cuff is warranted for two years The warranty does not cover damage from misuse or tampering 100 Satisfaction Guarantee If at any time you are not completely satisfied with the performance of this device call our BIOS Medical Hotline and speak with a customer serv...

Page 24: ...atteries size AA Main adapter DC 6V 600 mA optional Battery Lifetime Approximately 920 measurements Reference to standards EN1060 1 3 BHS Protocol IEC 60601 1 IEC 60601 1 11 IEC 60601 1 2 EMC This device complies with the requirements of the Medical Device Directive 93 42 EEC Technical alterations reserved Follow Instructions for Use This document provides important product operation and safety in...