BioSmart PV-WM Reader 

Operation Manual 

 

 

 

 

 

 

 

Summary of Contents for PV-WM-MFR

Page 1: ...Version 029 1 Date 03 2021 BioSmart PV WM Reader Operation Manual ...

Page 2: ...eparing the Product for Use 11 The Product Installation 12 2 3 1 Choosing the Reader Location 12 2 3 2 Guidelines for Cable Routing 12 2 3 3 Actions Immediately Before Connection 12 2 3 4 Installation Procedure 13 2 3 5 Connection to BioSmart UniPass Controller 17 Checking the Reader s Functionality 18 Reader Faults and Method of Its Elimination 18 PV WM Reader Settings 19 Procedure for Performing...

Page 3: ... This operating manual OM applies to the BioSmart PV WM reader and contains information on the principle of operation technical characteristics installation procedure and operating conditions as well as information on the conditions of transportation storage maintenance and maintenance of the reader in a working condition Installation adjustment and operation of the BioSmart PV WM reader should be...

Page 4: ...al Characteristics Technical characteristics are in the Table 1 Table 1 Reader technical characteristics Parameter Value Biometric ID Palm vein Biometric Scanner Type Optical infrared Built in RFID tag reader Yes Communication interface with the control computer Ethernet IEEE 802 3u 100BASE TX Maximum cable lenght Ethernet m 100 Indicators Buzzer and LED indicator DC supply voltage V 12 15 Maximum...

Page 5: ...er can be removed to provide access to the reader board The reader board is designed to connect the power supply and the BioSmart UniPass controller The palm vein scanner is designed to obtain users biometric data RFID tags reader is intended to read the applied RFID tags cards code Construction and Work The reader is designed as a functionally complete device in a standard case The appearance and...

Page 6: ...ccess settings prescribe to grant access to the appropriate employee BioSmart UniPass performs the actions specified in the working model for this situation and sends a message about successful identification to the reader BioSmart PV WM If the template is not found in the database or the access settings instruct to deny access then the controller performs other actions prescribed by the working m...

Page 7: ...ader status see Figure 3 Figure 3 The reader LED indicator The following display modes are set by default blue flashing palm card standby mode red single notification about unsuccessful identification red flashing there is no connection with the BioSmart UniPass controller or the reader is not tied to the controller green single notification about successful identification green flashing firmware ...

Page 8: ...Power supply 12V power supply 12V 3 Ethernet Ethernet connector with PoE support Ethernet connector for connection to the BioSmart UniPass controller Note The BioSmart PV WM reader is intended for use in conjunction with the BioSmart UniPass controller which powers the readers through PoE technology and therefore the GND and 12 V connectors on the reader are used only as backup power connectors Th...

Page 9: ...ach wire not less than 0 2 mm2 Power supply cable 50 Double core cable with a cross sectional area of each core not less than 0 75 mm2 Power supply from a DC voltage source is carried out at a voltage of 12V with an output current of 1A The allowable range of the supply voltage is 10 2 13 8V To prevent the device from malfunctioning due to incorrect power connection a protective diode is provided ...

Page 10: ...polyethylene foam The packaging used is intended for storage and transportation of the reader in accordance with the conditions specified in paragraph 5 Passport fasteners are additionally packed in a plastic bag Box size mm length 238 width 205 height 185 The cardboard box is non toxic and safe to handle It is a flammable material Non cross linked polyethylene foam liners and liner bags are highl...

Page 11: ...overed with a canopy roof or a special canopy for BioSmart PV WM all requirements of paragraph 2 3 have been met to ensure protection against dust and moisture ingress The device can be operated at a relative humidity of not more than 70 at a temperature of 25 С Moisture condensation is not allowed The device is not intended for use in aggressive and or explosive environments Operation of the read...

Page 12: ...readers it s not recommended to install the reader at a distance of less than 80 cm from other RFID readers and other sources of electromagnetic interference 4 When installing the reader on a metal surface the reading range of the RFID card may decrease 5 If the installation site is outdoors it s additionally necessary to ensure the presence of a canopy or a special visor over the reader which pre...

Page 13: ...ints of the reader by placing the mounting plate on the surface The dimensions of the mounting plate are shown in Figure 5 Figure 5 Mounting plate dimensions 4 If the installation is carried out without using a protective visor then drill holes in the marking points and install the dowels from the fastening kit If a protective visor for the BioSmart PV WM reader is used then it already has holes f...

Page 14: ...g the screws into the corresponding holes on the protective cover for BioSmart PV WM 7 Unscrew the screws on the back cover of the reader see Figure 7 remove the back cover Figure 7 Rear cover attachment points 8 Insert the Ethernet cable through the hole in the back cover of the reader insert the connector into the Ethernet port and secure the rear cover of the reader To achieve the declared IP54...

Page 15: ...ghtly clamped between the outer side of the back cover and the wide part of the nipple screw the fastening nut onto the connecting branch thread protruding from the back inner side of the reader back cover b with the sealed lead in installed connect the reader to the Ethernet network for which do the following insert the uncrimped end of the cable into the sealed lead in and stretch the cable to t...

Page 16: ...ing requirements attach the back cover to the reader case Make sure that the sealing gum didn t fall out of the special groove and was firmly pressed by the protrusion on the back cover side fix the back cover with screws see Figure 7 It s important to check that the sealing gum doesn t squeeze out of the special recess while tightening the screws Therefore tighten the screws on the back cover car...

Page 17: ...fix with screws at the bottom end Figure 11 Figure 11 Fixing the reader to the mounting plate 2 3 5 Connection to BioSmart UniPass Controller 1 The interaction between the BioSmart PV WM reader and the BioSmart UniPass controller is provided via the Ethernet interface 2 No more than two BioSmart PV WM readers may be connected to one BioSmart UniPass controller Readers connection scheme is on the F...

Page 18: ...their elimination Fault description Possible reason Elimination method 1 The reader doesn t turn on Insufficient supply voltage Connect to another power supply 2 Reader doesn t respond to applied palm card Connection with BioSmart UniPass controller isn t established Restart the BioSmart UniPass controller and reader on power supply Make sure the reader and controller are powered at the same time ...

Page 19: ...group assignment see the Biosmart Studio User Guide In the case when the measures taken didn t allow to eliminate the malfunction and in the event of malfunctions that are not described in Table 7 it s recommended to contact technical support PV WM Reader Settings After connecting the readers to the BioSmart UniPass controller and connecting the controller to the local network it s necessary to sp...

Page 20: ...ders indication will change to blue This indication mode indicates that the readers are ready for operation Procedure for Performing Product Application Tasks To start using the reader follow the steps connect the reader to the BioSmart UniPass controller via an Ethernet cable if it s necessary connect executive devices to the controller on the BioSmart UniPass controller select the working model ...

Page 21: ...e 16 RFID card reader field Depending on the access settings in the Biosmart Studio v5 software and the BioSmart UniPass controller work model settings successful or unsuccessful identification of an employee will be accompanied by a sound signal and or a signal from the LED indicator and or the actuator is triggered The BioSmart PV WM reader is designed for round the clock operation If it s neces...

Page 22: ...g plate unscrew the screws on the back cover of the reader and remove the back cover see Figure 7 pull out the Ethernet connector from the port The biometric access control system as a whole and the BioSmart PV WM reader as its integral part are not intended for operation in extreme conditions The customer should provide for redundant devices systems panic buttons etc that control locks turnstiles...

Page 23: ...pes of transport by air by rail in combination with each other and with road transport with a total number of transshipments from 3 to 4 by waterway shipment except for the sea together with air shipment Railway or road carriages with a total number of transshipments no more than four Storage and transportation of BioSmart ACS should be carried out at ambient temperatures from minus 40 to plus 50 ...

Page 24: ...Support support biosmart tech com 420 246 097 126 Skype BioSmart TechSupport 420 246 097 126 Konevova 2660 141 130 00 Prague Czech Republic www biosmart tech com sale biosmart tech com ...