HYDRAULIC SCHEMES
This scheme is a recommendation of the company Biotech. Please note that this scheme must be adapted to the local
conditions. For this reason, we cannot accept any liability for the function of the system
We reserve the right to make technical changes! It is essential to ensure that the return temperature of the boiler
does not fall below 55°C!
IMPORTANT NOTE:
Information without claim to completeness, no assumption of liability. Subject to typesetting and printing errors! Shut-off
devices, vents and safety measures are not shown in this schematic diagram. These must be installed specifically for the system in accordance with
standards and regulations! Chimney draught regulator with EX damper in the flue!
40/30
40/30
55°
not included in the
scope of delivery
Connection in the boiler
Pump
Mixer
HZS 524 X16
- Sensor cable 2-pole
HZS 524 X17
- Sensor cable 2-pole
HZS 524 X18
- Sensor cable 2-pole
HZS 532 X9
- Sensor cable 2-pole
HZS 532 X10
- Sensor cable 2-pole
HZS 532 X4
- Pump line 3x0,75mm²
HZS 524 X6
- Pump line 3x0,75mm²
HZS 532 X8
- Pump line 4x0,75mm²
Outdoor sensor
HZS 524 X16
Boiler
Buffer
HZS 532 X9
HZS 524 X18
HZS 524 X17
HZS 524 X6
HZS 532 X10
HZS 532 X4
HZS 532 X8
Heating circuit 2
Heating circuit 1
Connection
on the module
Heating circuit 2