en • English
23
5 Technical
Data
Mechanical Characteristics
Measurements for the housing
X-ray identification
BIO SF
Materials in contact with body tissue
• Housing: titanium
• Header: epoxy resin
• Plugs in the header: silicone
Electrical Characteristics
Electrically conductive surface
The device housing has the form of a flattened ellipsoid. The electrically conductive
area is 33 cm
2
.
Components and input values
Electrical characteristics determined at 37°C, 500 Ω:
Telemetry data
• MISC frequencies: 402 to 405 MHz
• Maximum power of transmission: < 25 µW (–16 dBm)
International radio certification
Devices with BIOTRONIK Home Monitoring
®
are equipped with an antenna for wireless
communication.
• Telemetry information for Canada:
This device must neither interfere with meteorological and earth resources tech-
nology satellites nor with meteorological stations working in the 400,150 to 406,000
MHZ band, and it must accept any interference received, including interference that
may cause undesired operation.
This device will be registered with Industry Canada under the following number:
IC: 4708A-PRIMUSNXT
The code IC in front of the certification/registration number only indicates that the
technical requirements for Industry Canada are met.
• Telemetry information for Japan:
In accordance with Japanese law, this device has been assigned an identification
number under the "Ordinance concerning certification of conformity with technical
regulations etc. of specified radio equipment", Article 2-1-8.
R: 202-LSB053
• Telemetry information for the USA:
Telemetry data for the USA: This transmitter is authorized by rule under the
Medical Device Radiocommunication Service (in part 95 of the FCC Rules) and must
not cause harmful interference to stations operating in the 400.150-406.000 MHz
band in the Meteorological Aids (i.e., transmitters and receivers used to communi-
cate weather data), the Meteorological Satellite, or the Earth Exploration Satellite
Services and must accept interference that may be caused by such stations,
including interference that may cause undesired operation. This transmitter shall
be used only in accordance with the FCC Rules governing the Medical Device Radio-
communication Service. Analog and digital voice communications are prohibited.
Although this transmitter has been approved by the Federal Communications
Commission, there is no guarantee that it will not receive interference or that any
particular transmission from this transmitter will be free from interference.
This device will be registered with Federal Communications Commission under the
following number:
FCC ID: QRIPRIMUSNXT
Device
W x H x D [mm]
Volume [cm
3
]
Mass [g]
Single-chamber SR(-T)
53 x 39 x 6.5
11
24
Dual-chamber DR(-T)
53 x 44.5 x 6.5
12
25
Triple-chamber HF-T
53 x 49 x 6.5
14
27
Note:
D = housing without header
Circuit
Hybrid electronics with VLSI-CMOS chip
Input impedance
> 10 kΩ
Pulse form
Biphasic, asymmetric
Polarity
Cathodic
401303--G_GA_Eluna-I-ProMRI_mul.book Page 23 Friday, October 2, 2015 4:57 PM