Start-up

2

Mounting

Translation of the original instructions

Recommended start-up sequence: I. Mounting

II. Connection

III. Initialisation

M

o

u

n

ti

n

g

*Factory setting

General

Safety instructions

1

The width of the AIR field can be set using the click-in plastic cover in front of
the detector's lens. (Dimensions at 2.2 m mounting high)

Detector without cover:
All light beams are active

Setting the AIR field width

(PrimeTec / PrimeScan)

Possible field width settings:

2.1

Pleas

e kee

p for

furthe

r use

!

Field width:
2.3 x 0.2 m

Quality

 

international

level

EN ISO
9001

*

E

N

G

LI

S

H

Observe the national and international regulations on door safety.
Only trained, qualified personnel may mount and start up the detector.
The unit may only be opened and repaired by Bircher Reglomat.
The unit may only be operated from a safety extra-low voltage (SELV) system with safe electrical separation.
Always consider the safety functions of your application as a whole, never just in relation to one individual section of the system.
The installer is responsible for carrying out a risk assessment and installing the detector and the door system correctly.
Avoid touching any electronic components.
The door drive and transom profile must be earthed correctly.

Hood

LED display

AIR light window

Detector without hood

LCD display

Microwave module

optics-cover

 

Detector electronic

Mounting holes

Cable bushing

a Button Mode (red)

b Button Data (black)

AIR adjusting device

LED1 AIR: red (left)

LED2 Microw.: green (rig.)

PrimeTec A

PrimeScan A

PrimeTec

PrimeScan

1.

Remove cover hood

3.

Lay and connect cable

2.

Set AIR field width (see chapter 2.1)

4.

Mount detector

A, B, G, H covered

E, G, H covered

C, D covered

1. Slide

A, D covered

A, B, D covered

E, F covered

2. Push & click!

A B C

D

E

F G H

A, B, G, H covered

A. B, G, H covered

Fe

ld

gr

ös

se

:0

.2

5

x

0.

2m

1.

2.

Fi

el

d

w

id

th

:1

.3

x

0.

2

m

Fi

el

d

w

id

th

:0

.2

5

x

0.

2

m

Fi

el

d

w

id

th

:1

x

0.

2

m

Fi

el

d

w

id

th

:1

x

0.

2

m

Fi

el

d

w

id

th

:0

.7

5

x

0.

2

m

Fi

el

d

w

id

th

:0

.7

5

x

0.

2

m

Fi

el

d

w

id

th

:0

.2

5

x

0.

2

m

Fi

el

d

w

id

th

:0

.2

5

x

0.

2

m

Mounting of the detector

2.2

1.

Position drill template

2.

Drill the holes, remove drill template

3.

Lay cable and mount detector

Combined detector AIR/Radar for opening and

protecting automatically controlled sliding doors

a

b

 

Reviews: