Measure Power Mode
125
Setting the Offset
To read unattenuated power when using a coupler or
attenuator, enter (in dB) the attenuation or coupling
factor. To convert percentages to dB, use the equation:
Attenuation(dB) = 10 x Log
10
[Attenuation(%) / 100]
5011-EF
The Bird 5011-EF uses frequency-dependent correc-
tion factors to provide more accurate measurements.
To use these, look at the label on the side of the sensor
and find the correction factor at the frequency being
measured. Add the correction factor to the other atten-
uation or coupling factors, and enter this as an offset
in the Site Analyzer.
The CCDF
Limit is
displayed at
the bottom
of the main
display
CCDF
0.00 %
Match
2.00 VSWR
100.00 Watts
CCDF Lim
Peak
-30.00 dBm
Refl
-30.00 dBm
Fwd
-30.00 dBm
Measure Power Mode
Sensor Connected
Meas Type
CCDF
MatchUnit
VSWR
PwrUnit
dBm
Display
Fwd