Bird Site Analyzer
48
Figure 18 Set Up for Cable Loss Measurement
5. Select the Freq soft key and set the frequency start
and stop to a range that is well beyond the normal
range of the antenna (refer to Setting the Mea-
surement Frequency, page 20).
Note:
For example, for a 450 MHz antenna,
set the start frequency at 400 and the stop
frequency at 500 MHz, for an 800 MHz
antenna, set the start frequency at 700 and the
stop frequency at 1,100 MHz.
800.00
MHz
1600.00
0.0
-60.0
C
abl
e Los
s (
0.
00
dB/
)
Calibration: OFF
Cable
Loss
Limit
Line
Scale
Freq
Measure Match
[
]
238 Pts
Cable Loss Mode
1
2
3
4
5
Step
Action
1
Press the Config key
2
Press the Scale soft key
3
Press the right or left scroll keys to select
Units
4
Press the up scroll key to open the units
list
5
Press the up or down scroll key to select
Cbl Loss then press Enter to accept the
selection
Summary of Contents for SITE ANALYZER SA-1700EX
Page 2: ...This page is not blank...
Page 8: ...Bird Site Analyzer vi...
Page 9: ...vii...
Page 30: ...Bird Site Analyzer 16...
Page 142: ...Bird Site Analyzer 128...
Page 148: ...Bird Site Analyzer 134...
Page 159: ...Maintenance 145 Measured Return Loss dB...
Page 167: ...Maintenance 153 the number of data points you wish measure 238 475 949...