Fault Location Mode
57
Figure 20 Setting the Frequency Span and the Cen-
ter Frequency
Start: 1100.00 MHz
Stop: 1300.00 MHz
Center: 1200.00 MHz
Span:
MHz
200.00
Band List: Custom
1100.00
MHz
1300.00
Cable
Loss
Limit
Line
Scale
Freq
10.00
1.00
V
S
W
R
(0.00/ )
Measure Match
[
]
238 Pts
2
5
3
4
6
7
1
Step
Action
1
Press the Config key
2
Press the Freq soft key
3
For both Span and Center, scroll to select
the item (Span or Center)
4
Enter the Span value determined from the
table earlier. Enter the value for the center
frequency as determined in instruction
Step 3.
5
After you enter the Span value, press the
Enter key. After you enter the Center
value, press Enter.
6
Press the Mode key
7
Press the Fault Location soft key
Summary of Contents for SITE ANALYZER SA-1700EX
Page 2: ...This page is not blank...
Page 8: ...Bird Site Analyzer vi...
Page 9: ...vii...
Page 30: ...Bird Site Analyzer 16...
Page 142: ...Bird Site Analyzer 128...
Page 148: ...Bird Site Analyzer 134...
Page 159: ...Maintenance 145 Measured Return Loss dB...
Page 167: ...Maintenance 153 the number of data points you wish measure 238 475 949...